High sensitivity detectors in photoacoustic imaging: how close are we to the ultimate limits of NEP? (Conference Presentation)

Photoacoustic (PA) imaging provides detailed images of soft tissue but achieving multi-cm scale penetration depth is challenging as the signals encountered are extremely weak, necessitating highly-sensitive detectors. Unfortunately, due to a range of factors including the challenging nature of detector characterisation and incomplete reporting, it is difficult to effectively compare detectors and select the best one for achieving maximal penetration depth. This talk will address this by providing a rigorous review of the capabilities of PA detectors, demonstrate how the choice of detector critically impacts upon PA image depth and quality, and elucidate the ultimate limits of PA detection sensitivity.

Authors

Institutions

Publication Details

Published
2025-03-20
DOI
https://doi.org/10.1117/12.3048395
Citations
1
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High sensitivity detectors in photoacoustic imaging: how close are we to the ultimate limits of NEP? (Conference Presentation)

Olumide Ogunlade, Paul C. Beard, James A. Guggenheim, Thomas J. Allen
1 citations
Photoacoustic and Ultrasonic Imaging
0.67
article

High sensitivity detectors in photoacoustic imaging: how close are we to the ultimate limits of NEP? (Conference Presentation)

Olumide Ogunlade, Paul C. Beard, James A. Guggenheim, Thomas J. Allen
article en
1 citations

Abstract

Photoacoustic (PA) imaging provides detailed images of soft tissue but achieving multi-cm scale penetration depth is challenging as the signals encountered are extremely weak, necessitating highly-sensitive detectors. Unfortunately, due to a range of factors including the challenging nature of detector characterisation and incomplete reporting, it is difficult to effectively compare detectors and select the best one for achieving maximal penetration depth. This talk will address this by providing a rigorous review of the capabilities of PA detectors, demonstrate how the choice of detector critically impacts upon PA image depth and quality, and elucidate the ultimate limits of PA detection sensitivity.

University College London (GB), University of Birmingham (GB)
Openalex Percentile: Top 34%
Photoacoustic and Ultrasonic Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High sensitivity detectors in photoacoustic imaging: how close are we to the ultimate limits of NEP? (Conference Presentation) — Olumide Ogunlade, Paul C. Beard, et al. · (2025) | TGRS Research Map | TGRS