Hemodynamic analysis of fusiform-shaped inferior vena cava filter with thrombus capture: A computational fluid dynamics study

The placement of an inferior vena cava filter (IVCF) has been an effective treatment to prevent fatal pulmonary embolism in clinical practice for decades. Fusiform-shaped filter is one of the main types of IVCFs, but its hemodynamics with thrombus capture has not been clearly understood. In this paper, computational fluid dynamics (CFD) simulations are used to investigate the characteristics of blood flow with thrombi over TrapEase and OptEase filters, respectively, two frequently used fusiform-shaped IVCFs in clinic therapy. The blood flow with thrombi is characterized by the Eulerian two-phase flow model, in which the blood is regarded as a non-Newtonian fluid. CFD results show that there are significant stagnation zones downstream of both filters, with the lengths nearly up to 12 times the diameter of the IVC. The no-slip wall conditions of filter wires induce a viscous block effect and result in blood flow acceleration inside the fusiform-shaped filter. The viscous drag contributes predominantly to the total flow resistance of fusiform-shaped filter, about three times the pressure drag. The presence of thrombi does not greatly affect the hemodynamics, but reduces the nearby blood flow speed when captured by the filter. The thrombi primarily accumulate at the end of the filter, increasing both viscous and pressure drag, leading to a 10%–12% increase in total flow resistance. The present study provides common insights into the hemodynamics with thrombus capture of the fusiform-shaped filter, which would contribute to its future clinical use and design improvement.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2025-03-01
DOI
https://doi.org/10.1063/5.0264241
Citations
3
Primary Topic
Venous Thromboembolism Diagnosis and Management
Type
article
Field-Weighted Citation Impact
5.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hemodynamic analysis of fusiform-shaped inferior vena cava filter with thrombus capture: A computational fluid dynamics study

Chun‐Hian Lee, Jingying Wang, Shuai Chen, Mingrui Li
3 citations
Physics of Fluids
Venous Thromboembolism Diagnosis and Management
5.61
article

Hemodynamic analysis of fusiform-shaped inferior vena cava filter with thrombus capture: A computational fluid dynamics study

Chun‐Hian Lee, Jingying Wang, Shuai Chen, Mingrui Li
article en
3 citations

Abstract

The placement of an inferior vena cava filter (IVCF) has been an effective treatment to prevent fatal pulmonary embolism in clinical practice for decades. Fusiform-shaped filter is one of the main types of IVCFs, but its hemodynamics with thrombus capture has not been clearly understood. In this paper, computational fluid dynamics (CFD) simulations are used to investigate the characteristics of blood flow with thrombi over TrapEase and OptEase filters, respectively, two frequently used fusiform-shaped IVCFs in clinic therapy. The blood flow with thrombi is characterized by the Eulerian two-phase flow model, in which the blood is regarded as a non-Newtonian fluid. CFD results show that there are significant stagnation zones downstream of both filters, with the lengths nearly up to 12 times the diameter of the IVC. The no-slip wall conditions of filter wires induce a viscous block effect and result in blood flow acceleration inside the fusiform-shaped filter. The viscous drag contributes predominantly to the total flow resistance of fusiform-shaped filter, about three times the pressure drag. The presence of thrombi does not greatly affect the hemodynamics, but reduces the nearby blood flow speed when captured by the filter. The thrombi primarily accumulate at the end of the filter, increasing both viscous and pressure drag, leading to a 10%–12% increase in total flow resistance. The present study provides common insights into the hemodynamics with thrombus capture of the fusiform-shaped filter, which would contribute to its future clinical use and design improvement.

Physics of FluidsVol. 37(3)
Shandong University (CN), Jinan Central Hospital (CN), Jinan Stomatological Hospital (CN), Beihang University (CN)
Natural Science Foundation of Shandong Province
Openalex Percentile: Top 4%
Venous Thromboembolism Diagnosis and Management
5.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.