Assessment of anti-cancer drugs in 3D in vitro models using OCT-derived quantitative metrics (Conference Presentation)

Ninety percent of drugs fail during clinical trials. Of these failures, approximately 50% fail due to lack of clinical efficacy. Recent developments in in vitro models such as 3D spheroids and organoids have led to some improvements in failure rates, but the relative lack of standardized evaluation methods for 3D cultures limits their utility in high-throughput screening. In this study we investigate the potential of optical coherence tomography as a tool for assessing drug efficacy in 3D in vitro models. First, we consider a 3D convolutional neural network-based classification model for assessing drug efficacy based on raw OCT volumes. Additionally, we investigate several quantitative OCT metrics for assessing the effectiveness of the drugs including spheroid volume, OCT-derived optical attenuation coefficient, and analysis of speckle statistics. Our results underscore the possibility that OCT could be used for high-throughput screening of drugs using 3D in vitro models.

Authors

Publication Details

Published
2025-03-20
DOI
https://doi.org/10.1117/12.3041760
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of anti-cancer drugs in 3D in vitro models using OCT-derived quantitative metrics (Conference Presentation)

Kim Holmstrøm, Gavrielle R. Untracht, Jan P. Kamiński, Katrine Jensen et al.
Advanced Fluorescence Microscopy Techniques
article

Assessment of anti-cancer drugs in 3D in vitro models using OCT-derived quantitative metrics (Conference Presentation)

Kim Holmstrøm, Gavrielle R. Untracht, Jan P. Kamiński, Katrine Jensen, Oswald F Wagner, Peter E. Andersen, Boye Schnack Nielsen
article en

Abstract

Ninety percent of drugs fail during clinical trials. Of these failures, approximately 50% fail due to lack of clinical efficacy. Recent developments in in vitro models such as 3D spheroids and organoids have led to some improvements in failure rates, but the relative lack of standardized evaluation methods for 3D cultures limits their utility in high-throughput screening. In this study we investigate the potential of optical coherence tomography as a tool for assessing drug efficacy in 3D in vitro models. First, we consider a 3D convolutional neural network-based classification model for assessing drug efficacy based on raw OCT volumes. Additionally, we investigate several quantitative OCT metrics for assessing the effectiveness of the drugs including spheroid volume, OCT-derived optical attenuation coefficient, and analysis of speckle statistics. Our results underscore the possibility that OCT could be used for high-throughput screening of drugs using 3D in vitro models.

Good health and well-being
Openalex Percentile: Top 95%
Advanced Fluorescence Microscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of anti-cancer drugs in 3D in vitro models using OCT-derived quantitative metrics (Conference Presentation) — Kim Holmstrøm, Gavrielle R. Untracht, et al. · (2025) | TGRS Research Map | TGRS