Toward efficient signal extraction for deep tissue blood flow using parallelized diffuse correlation spectroscopy (Conference Presentation)

Diffuse correlation spectroscopy (DCS) is an optical technique that allows for non-invasive measurements of tissue perfusion, and is often used for neuromonitoring applications. However, a major challenge of DCS is low SNR for deep tissue measurements. Recent works have demonstrated the potential for SPAD arrays to provide significant SNR increases by averaging autocorrelation signals from individual speckles. To fully exploit the potential of SPAD array signals, in this work we present alternative methods to recovering the desired blood flow signal and demonstrate their effectiveness in reducing the required sampling time or improving computation speed.

Authors

Institutions

Publication Details

Published
2025-03-20
DOI
https://doi.org/10.1117/12.3043566
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Toward efficient signal extraction for deep tissue blood flow using parallelized diffuse correlation spectroscopy (Conference Presentation)

Lucas Kreiß, Edoardo Charbon, Melissa M. Wu, Claudio Bruschini et al.
Spectroscopy Techniques in Biomedical and Chemical Research
article

Toward efficient signal extraction for deep tissue blood flow using parallelized diffuse correlation spectroscopy (Conference Presentation)

Lucas Kreiß, Edoardo Charbon, Melissa M. Wu, Claudio Bruschini, Roarke Horstmeyer, Michael Wayne
article en

Abstract

Diffuse correlation spectroscopy (DCS) is an optical technique that allows for non-invasive measurements of tissue perfusion, and is often used for neuromonitoring applications. However, a major challenge of DCS is low SNR for deep tissue measurements. Recent works have demonstrated the potential for SPAD arrays to provide significant SNR increases by averaging autocorrelation signals from individual speckles. To fully exploit the potential of SPAD array signals, in this work we present alternative methods to recovering the desired blood flow signal and demonstrate their effectiveness in reducing the required sampling time or improving computation speed.

Duke University (US), École Polytechnique Fédérale de Lausanne (CH)
Openalex Percentile: Top 95%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.