Influence of surface effect on the resistance of electrodes of electrosurgical instruments

The paper presents a study of the influence of the surface effect on the environments involved in electrosurgical interventions. Taking into account the influence of the surface effect when designing new electrosurgical instruments allows reducing overheating and necrosis of living biological tissues, which is of practical interest and is a topical task. The authors plot frequency dependences of the depth of the surface layers of electrodes and biological tissues. For biological tissue, the depth of the surface layer is at a frequency of 440 kHz is considerable, about 1 m. For copper, at such a frequency, the depth of the surface layer is 0. 1 mm. Using the example of round and rectangular electrodes made of copper and stainless steel 410, in a wide frequency range (1 kHz – 1 MHz), the resistance values of these electrodes are calculated. The work shows that increasing the outer perimeter of the electrode reduces its resistance. Thus, increasing the total length of the outer perimeter of the electrode, allows you to increase its effective area conducting high-frequency current, which creates conditions for increasing the efficiency of electrosurgical instruments.

Authors

Institutions

Publication Details

Journal
Technology and design in electronic equipment
Published
2024-12-27
DOI
https://doi.org/10.15222/tkea2024.3-4.42
Primary Topic
Thyroid and Parathyroid Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of surface effect on the resistance of electrodes of electrosurgical instruments

Андрій Дубко, Олександр Романенко
Technology and design in electronic equipment
Thyroid and Parathyroid Surgery
article

Influence of surface effect on the resistance of electrodes of electrosurgical instruments

Андрій Дубко, Олександр Романенко
article en

Abstract

The paper presents a study of the influence of the surface effect on the environments involved in electrosurgical interventions. Taking into account the influence of the surface effect when designing new electrosurgical instruments allows reducing overheating and necrosis of living biological tissues, which is of practical interest and is a topical task. The authors plot frequency dependences of the depth of the surface layers of electrodes and biological tissues. For biological tissue, the depth of the surface layer is at a frequency of 440 kHz is considerable, about 1 m. For copper, at such a frequency, the depth of the surface layer is 0. 1 mm. Using the example of round and rectangular electrodes made of copper and stainless steel 410, in a wide frequency range (1 kHz – 1 MHz), the resistance values of these electrodes are calculated. The work shows that increasing the outer perimeter of the electrode reduces its resistance. Thus, increasing the total length of the outer perimeter of the electrode, allows you to increase its effective area conducting high-frequency current, which creates conditions for increasing the efficiency of electrosurgical instruments.

Technology and design in electronic equipment(3–4)
Physical Sciences (United States) (US)
Openalex Percentile: Top 53%
Thyroid and Parathyroid Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.