[Comparison and application of direct and indirect methods in establishing reference intervals for coagulation tests].

This study aimed to establish adult reference intervals for coagulation parameters using the CN-6000 fully automated coagulation analyzer. It also compared the applicability of direct and indirect methods in different populations. A cross-sectional and retrospective design was employed. The direct method included patients from the colorectal surgery and dermatology departments, as well as healthy participants from phase I clinical trials, admitted to the West Campus of China-Japan Friendship Hospital from April to December 2023. Participants were divided into two age groups: younger adults (18-64 years) and older adults (≥65 years). Coagulation parameters were tested, and reference intervals were determined. The indirect method applied the refineR algorithm to analyze coagulation data from non-ICU patients during the same period. The performance of both methods was evaluated in healthy participants, relatively healthy patients, and patients with high disease prevalence. The results showed that the direct method yielded similar reference intervals for APTT, PT, and TT in younger and older groups, with combined intervals of 23.7-31.2 seconds, 10.4-12.8 seconds, and 14.7-17.5 seconds, respectively. However, the Fib showed a significant difference between the two groups (<i>U</i>=1 052 023, <i>P</i><0.01), and separate reference intervals were established: 1.7-4.5 g/L for the younger group and 2.1-4.6 g/L for the older group. The reference intervals derived by the indirect method are similar to those from the direct method: APTT 23.8-31.4 seconds, PT 10.4-13.0 seconds, TT 14.5-17.4 seconds, and Fib 1.8-4.3 g/L (18-64 years) and 2.1-4.5 g/L (≥65 years). In relatively healthy patients, the reference intervals obtained by both methods were comparable, but significant differences were observed in patients with high disease prevalence. In conclusion, this study established localized reference intervals for the CN-6000 fully automated coagulation analyzer. The indirect method can serve as an alternative to the direct method in healthy and relatively healthy populations. However, its applicability in populations with high disease prevalence is limited and requires cautious interpretation in the context of clinical settings.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2025-03-06
DOI
https://doi.org/10.3760/cma.j.cn112150-20240923-00764
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Comparison and application of direct and indirect methods in establishing reference intervals for coagulation tests].

Y T Cao, Jinchuan Zheng, Peiyan Wang, Jing Li et al.
PubMed
Clinical Laboratory Practices and Quality Control
article

[Comparison and application of direct and indirect methods in establishing reference intervals for coagulation tests].

Y T Cao, Jinchuan Zheng, Peiyan Wang, Jing Li, Qunsheng Cao
article en

Abstract

This study aimed to establish adult reference intervals for coagulation parameters using the CN-6000 fully automated coagulation analyzer. It also compared the applicability of direct and indirect methods in different populations. A cross-sectional and retrospective design was employed. The direct method included patients from the colorectal surgery and dermatology departments, as well as healthy participants from phase I clinical trials, admitted to the West Campus of China-Japan Friendship Hospital from April to December 2023. Participants were divided into two age groups: younger adults (18-64 years) and older adults (≥65 years). Coagulation parameters were tested, and reference intervals were determined. The indirect method applied the refineR algorithm to analyze coagulation data from non-ICU patients during the same period. The performance of both methods was evaluated in healthy participants, relatively healthy patients, and patients with high disease prevalence. The results showed that the direct method yielded similar reference intervals for APTT, PT, and TT in younger and older groups, with combined intervals of 23.7-31.2 seconds, 10.4-12.8 seconds, and 14.7-17.5 seconds, respectively. However, the Fib showed a significant difference between the two groups (<i>U</i>=1 052 023, <i>P</i><0.01), and separate reference intervals were established: 1.7-4.5 g/L for the younger group and 2.1-4.6 g/L for the older group. The reference intervals derived by the indirect method are similar to those from the direct method: APTT 23.8-31.4 seconds, PT 10.4-13.0 seconds, TT 14.5-17.4 seconds, and Fib 1.8-4.3 g/L (18-64 years) and 2.1-4.5 g/L (≥65 years). In relatively healthy patients, the reference intervals obtained by both methods were comparable, but significant differences were observed in patients with high disease prevalence. In conclusion, this study established localized reference intervals for the CN-6000 fully automated coagulation analyzer. The indirect method can serve as an alternative to the direct method in healthy and relatively healthy populations. However, its applicability in populations with high disease prevalence is limited and requires cautious interpretation in the context of clinical settings.

PubMedVol. 59(3)
China-Japan Friendship Hospital (CN)
Openalex Percentile: Top 93%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.