Prediction of cardiovascular vital signs using laser speckle flow index signals from a wireless wearable device (Conference Presentation)

Cardiovascular complications account for nearly half of US and global maternal deaths. Monitoring cardiac output (CO), systemic vascular resistance (SVR), and mean arterial pressure (MAP) would enable early detection of cardiac complications. A low-cost wearable laser speckle flow index (LSFI) sensor that captures pulsatile waveforms across the cardiac cycle was developed to accurately estimate CO, SVR, and MAP. Waveforms were collected from swine undergoing blood removal and human subjects undergoing exercise. From these waveforms, features were extracted and used to train multivariate regression models to predict CO, MAP, and SVR. In swine, average absolute errors of 2.13 L/min, 9.0 mmHg, and 464 dynes/sec/cm-5 were produced, respectively. The correlation coefficients for a regression between true and predicted values were r=0.79, r=0.88, and r=0.68, respectively. In human subjects CO and SVR were predicted and produced absolute errors and correlation coefficients of 1.52 L/min and r=0.80 and 278 dynes/sec/cm-5 and r=0.66, respectively.

Authors

Institutions

Publication Details

Published
2025-03-20
DOI
https://doi.org/10.1117/12.3042213
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prediction of cardiovascular vital signs using laser speckle flow index signals from a wireless wearable device (Conference Presentation)

C. O’Brien, Madison Carlgren, Peinan Zhao, Toi Collins et al.
Non-Invasive Vital Sign Monitoring
article

Prediction of cardiovascular vital signs using laser speckle flow index signals from a wireless wearable device (Conference Presentation)

C. O’Brien, Madison Carlgren, Peinan Zhao, Toi Collins, Leonid Shmuylovich, Todd Pavek, Francesca Bonetta-Misteli, Antonina I. Frolova, Miranda Bagar, Folaolowashewa Shofu
article en

Abstract

Cardiovascular complications account for nearly half of US and global maternal deaths. Monitoring cardiac output (CO), systemic vascular resistance (SVR), and mean arterial pressure (MAP) would enable early detection of cardiac complications. A low-cost wearable laser speckle flow index (LSFI) sensor that captures pulsatile waveforms across the cardiac cycle was developed to accurately estimate CO, SVR, and MAP. Waveforms were collected from swine undergoing blood removal and human subjects undergoing exercise. From these waveforms, features were extracted and used to train multivariate regression models to predict CO, MAP, and SVR. In swine, average absolute errors of 2.13 L/min, 9.0 mmHg, and 464 dynes/sec/cm-5 were produced, respectively. The correlation coefficients for a regression between true and predicted values were r=0.79, r=0.88, and r=0.68, respectively. In human subjects CO and SVR were predicted and produced absolute errors and correlation coefficients of 1.52 L/min and r=0.80 and 278 dynes/sec/cm-5 and r=0.66, respectively.

Washington University in St. Louis (US)
Openalex Percentile: Top 95%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.