Single-shot double-pulse range-gated 3D imaging

Range-gated imaging has the advantages of long imaging distance, high signal-to-noise ratio, and good environmental adaptability.However, conventional range-gated imaging utilizes a single laser pulse illumination modality, which can only resolve a single depth of ranging in one shot.Three-dimensional (3D) imaging has to be obtained from multiple shots, which limits its real-time performance.Here, an approach of range-gated imaging using a specific double-pulse sequence is proposed to overcome this limitation.With the help of a calibrated double-pulse range-intensity profile, the depth of static targets can be calculated from the measurement of a single shot.Moreover, the double-pulse approach is beneficial for real-time depth estimation of dynamic targets.Experimental results indicate that, compared to the conventional approach, the depth of field and depth resolution are increased by 1.36 and 2.20 times, respectively.It is believed that the proposed double-pulse approach provides a potential new paradigm for range-gated 3D imaging.

Authors

Institutions

Publication Details

Journal
Chinese Optics Letters
Published
2025-01-01
DOI
https://doi.org/10.3788/col202523.031101
Citations
1
Primary Topic
Advanced Optical Sensing Technologies
Type
article
Field-Weighted Citation Impact
1.19

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single-shot double-pulse range-gated 3D imaging

Baoqing Sun, Yongkai Yin, Hua Fan, Junquan Sun et al.
1 citations
Chinese Optics Letters
Advanced Optical Sensing Technologies
1.19
article

Single-shot double-pulse range-gated 3D imaging

Baoqing Sun, Yongkai Yin, Hua Fan, Junquan Sun, Xiaolei Zhang
article en
1 citations

Abstract

Range-gated imaging has the advantages of long imaging distance, high signal-to-noise ratio, and good environmental adaptability.However, conventional range-gated imaging utilizes a single laser pulse illumination modality, which can only resolve a single depth of ranging in one shot.Three-dimensional (3D) imaging has to be obtained from multiple shots, which limits its real-time performance.Here, an approach of range-gated imaging using a specific double-pulse sequence is proposed to overcome this limitation.With the help of a calibrated double-pulse range-intensity profile, the depth of static targets can be calculated from the measurement of a single shot.Moreover, the double-pulse approach is beneficial for real-time depth estimation of dynamic targets.Experimental results indicate that, compared to the conventional approach, the depth of field and depth resolution are increased by 1.36 and 2.20 times, respectively.It is believed that the proposed double-pulse approach provides a potential new paradigm for range-gated 3D imaging.

Chinese Optics LettersVol. 23(3)
Qilu University of Technology (CN), Shandong University (CN), Shandong Academy of Sciences (CN)
National Natural Science Foundation of China, Chinesisch-Deutsche Zentrum für Wissenschaftsförderung, National Key Research and Development Program of China
Openalex Percentile: Top 23%
Advanced Optical Sensing Technologies
1.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Single-shot double-pulse range-gated 3D imaging — Baoqing Sun, Yongkai Yin, et al. · Chinese Optics Letters (2025) | TGRS Research Map | TGRS