Ultrasound light waveguiding to increase fluorescence of a hidden target

Detection, imaging and treatment of targets in deep tissues are severely limited by extremely small amount of light reaching them, with most losses due to light scattering in tissues. Ultrasound light waveguiding has been recently demonstrated as a promising technique to counteract scattering and increase the amount of light available at depth by recollecting scattered photons and guiding them further. Here we use this technique to increase the intensity of fluorescence, collected from a target hidden behind a 3 mm thick scattering phantom. Ultrasound light waveguide is set up in a phantom using a common linear array transducer arranged transversally to the light beam, and fluorescence is measured in transmission. We use a pulsed 532 nm light as an excitation source common for photoacoustic imaging and demonstrate ultrasound light waveguiding induced increase of detected fluorescence.

Authors

Publication Details

Published
2025-03-20
DOI
https://doi.org/10.1117/12.3043104
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasound light waveguiding to increase fluorescence of a hidden target

Maxim Cherkashin, Georg Schmitz, Carsten Brenner, Martin R. Hofmann et al.
4 links
Photoacoustic and Ultrasonic Imaging
article

Ultrasound light waveguiding to increase fluorescence of a hidden target

Maxim Cherkashin, Georg Schmitz, Carsten Brenner, Martin R. Hofmann, Volodymyr Rohovets
article en

Abstract

Detection, imaging and treatment of targets in deep tissues are severely limited by extremely small amount of light reaching them, with most losses due to light scattering in tissues. Ultrasound light waveguiding has been recently demonstrated as a promising technique to counteract scattering and increase the amount of light available at depth by recollecting scattered photons and guiding them further. Here we use this technique to increase the intensity of fluorescence, collected from a target hidden behind a 3 mm thick scattering phantom. Ultrasound light waveguide is set up in a phantom using a common linear array transducer arranged transversally to the light beam, and fluorescence is measured in transmission. We use a pulsed 532 nm light as an excitation source common for photoacoustic imaging and demonstrate ultrasound light waveguiding induced increase of detected fluorescence.

Openalex Percentile: Top 95%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.