Understanding the impact of patient-specific geometries on Cherenkov emission-to-dose relationship during external beam radiation therapy (EBRT)

Cherenkov photons generated during External Beam Radiation Therapy (EBRT) provide real-time optical feedback on the radiation field distribution. While Cherenkov emission correlates with radiation dose, patient-specific anatomical variations, particularly breast geometry, introduce inconsistencies in the Cherenkov emission-to-dose ratio. This study investigates the influence of breast contour, specifically curvature, on the accuracy of Cherenkov-based dosimetry. To address these variations, patient-specific Cherenkov imaging data is corrected using Lambertian geometric correction and compared with the planned radiation dose to derive a correction function as a function of breast curvature. Additionally, scintillator-based Cherenkov imaging data is analyzed and compared with in vivo dosimetry to assess the feasibility of scintillators as real-time dosimeters for EBRT.

Authors

Institutions

Publication Details

Published
2025-03-20
DOI
https://doi.org/10.1117/12.3048321
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Understanding the impact of patient-specific geometries on Cherenkov emission-to-dose relationship during external beam radiation therapy (EBRT)

Brook K. Byrd, Lisha Chen, Daniel A. Alexander, Timothy C. Zhu et al.
Advanced Radiotherapy Techniques
article

Understanding the impact of patient-specific geometries on Cherenkov emission-to-dose relationship during external beam radiation therapy (EBRT)

Brook K. Byrd, Lisha Chen, Daniel A. Alexander, Timothy C. Zhu, Baozhu Lu, Brian W. Pogue, John P. Plastaras, Taoran Li, Yifeng Zhu
article en

Abstract

Cherenkov photons generated during External Beam Radiation Therapy (EBRT) provide real-time optical feedback on the radiation field distribution. While Cherenkov emission correlates with radiation dose, patient-specific anatomical variations, particularly breast geometry, introduce inconsistencies in the Cherenkov emission-to-dose ratio. This study investigates the influence of breast contour, specifically curvature, on the accuracy of Cherenkov-based dosimetry. To address these variations, patient-specific Cherenkov imaging data is corrected using Lambertian geometric correction and compared with the planned radiation dose to derive a correction function as a function of breast curvature. Additionally, scintillator-based Cherenkov imaging data is analyzed and compared with in vivo dosimetry to assess the feasibility of scintillators as real-time dosimeters for EBRT.

Vol. 13309
University of Pennsylvania (US)
National Institutes of Health
Openalex Percentile: Top 93%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Understanding the impact of patient-specific geometries on Cherenkov emission-to-dose relationship during external beam radiation therapy (EBRT) — Brook K. Byrd, Lisha Chen, et al. · (2025) | TGRS Research Map | TGRS