Hydrophilic Particles Exit While Hydrophobic Particles Persist Following In Vivo Biodegradation of Nanoparticle‐Laden Polymeric Devices

Longitudinally monitoring biomedical devices postimplantation can improve patient outcomes by allowing targeted intervention during healing. Most polymeric devices are not visible via biomedical imaging technologies. Incorporation of nanoparticle contrast agents into polymer matrices creates imageable devices, but understanding and controlling nanoparticle clearance from the implant site after polymer degradation is needed for clinical translation. To achieve homogeneous distribution throughout biomedical devices, nanoparticle surface chemistry, particularly hydrophobicity, is often manipulated to generate stable suspensions during manufacture. As nanoparticle surface chemistry is a key parameter determining blood circulation, the effects of nanoparticle hydrophilicity on tissue clearance of nanoparticles from implant sites following polymeric device degradation are investigated. Hydrophilic and hydrophobic radiopaque tantalum oxide (TaO x ) nanoparticles are incorporated at 10 wt% tantalum into gelatin phantoms. In vitro, the diffusion coefficient of released hydrophilic nanoparticles after phantom degradation is significantly greater than hydrophobic nanoparticles, 1.29 ± 0.26 × 10 −5 and 0.40 ± 0.16 × 10 −5 cm 2 s −1 , respectively. After subcutaneous implantation in mouse and subsequent phantom degradation, hydrophilic nanoparticles clear skin and muscle tissue within 24 h, whereas hydrophobic nanoparticles remained at the implant site >14 days without change in radiopacity. This clearly demonstrates that nanoparticle surface chemistry must be balanced for initial device manufacturing and final excretion.

Authors

Institutions

Publication Details

Journal
Advanced NanoBiomed Research
Published
2025-03-19
DOI
https://doi.org/10.1002/anbr.202500005
Citations
1
Primary Topic
Nanoparticles: synthesis and applications
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hydrophilic Particles Exit While Hydrophobic Particles Persist Following In Vivo Biodegradation of Nanoparticle‐Laden Polymeric Devices

Matti Kiupel, Peter J. Bonitatibus, Erik M. Shapiro, Kendell M. Pawelec et al.
1 citations
Advanced NanoBiomed Research
Nanoparticles: synthesis and applications
0.52
article

Hydrophilic Particles Exit While Hydrophobic Particles Persist Following In Vivo Biodegradation of Nanoparticle‐Laden Polymeric Devices

Matti Kiupel, Peter J. Bonitatibus, Erik M. Shapiro, Kendell M. Pawelec, Jeremy M.L. Hix
article en
1 citations

Abstract

Longitudinally monitoring biomedical devices postimplantation can improve patient outcomes by allowing targeted intervention during healing. Most polymeric devices are not visible via biomedical imaging technologies. Incorporation of nanoparticle contrast agents into polymer matrices creates imageable devices, but understanding and controlling nanoparticle clearance from the implant site after polymer degradation is needed for clinical translation. To achieve homogeneous distribution throughout biomedical devices, nanoparticle surface chemistry, particularly hydrophobicity, is often manipulated to generate stable suspensions during manufacture. As nanoparticle surface chemistry is a key parameter determining blood circulation, the effects of nanoparticle hydrophilicity on tissue clearance of nanoparticles from implant sites following polymeric device degradation are investigated. Hydrophilic and hydrophobic radiopaque tantalum oxide (TaO x ) nanoparticles are incorporated at 10 wt% tantalum into gelatin phantoms. In vitro, the diffusion coefficient of released hydrophilic nanoparticles after phantom degradation is significantly greater than hydrophobic nanoparticles, 1.29 ± 0.26 × 10 −5 and 0.40 ± 0.16 × 10 −5 cm 2 s −1 , respectively. After subcutaneous implantation in mouse and subsequent phantom degradation, hydrophilic nanoparticles clear skin and muscle tissue within 24 h, whereas hydrophobic nanoparticles remained at the implant site >14 days without change in radiopacity. This clearly demonstrates that nanoparticle surface chemistry must be balanced for initial device manufacturing and final excretion.

Advanced NanoBiomed ResearchVol. 5(6)
Rensselaer Polytechnic Institute (US), Michigan State University (US)
National Institutes of Health
Openalex Percentile: Top 41%
Nanoparticles: synthesis and applications
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.