High resolution wearable FBG-based sensing device for cardiac rate and blood pressure monitoring

This study introduces a method for monitoring cardiac rate and blood pressure using fiber Bragg grating (FBG) sensors. A custom FBG array with two multiplexed sensors was developed to measure pulse waves at different body locations. The FBG sensors detect cardiac rate by capturing pulse vibrations, while blood pressure is inferred from the pulse wave signals. Variations in systolic blood pressure affect the time required for a single pulse wave to travel between two body sites. By calibrating the time difference of pulse waves at different locations with systolic pressure, blood pressure can be accurately estimated. The device enables real-time cardiovascular monitoring with a 5 kHz sampling rate. Experimental results demonstrate a correlation coefficient of 0.65 between predicted and actual systolic blood pressure, with a standard error of 4 mmHg. Compared to traditional sensing devices, this FBG-based system is more compact, offers higher resolution, and provides faster response times.

Authors

Publication Details

Published
2025-03-20
DOI
https://doi.org/10.1117/12.3038758
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High resolution wearable FBG-based sensing device for cardiac rate and blood pressure monitoring

Shuda Zhong, Kevin P. Chen, Zekun Wu, Kehao Zhao et al.
1 citations
Non-Invasive Vital Sign Monitoring
0.67
article

High resolution wearable FBG-based sensing device for cardiac rate and blood pressure monitoring

Shuda Zhong, Kevin P. Chen, Zekun Wu, Kehao Zhao, Qirui Wang, Guangqun Ma
article en
1 citations

Abstract

This study introduces a method for monitoring cardiac rate and blood pressure using fiber Bragg grating (FBG) sensors. A custom FBG array with two multiplexed sensors was developed to measure pulse waves at different body locations. The FBG sensors detect cardiac rate by capturing pulse vibrations, while blood pressure is inferred from the pulse wave signals. Variations in systolic blood pressure affect the time required for a single pulse wave to travel between two body sites. By calibrating the time difference of pulse waves at different locations with systolic pressure, blood pressure can be accurately estimated. The device enables real-time cardiovascular monitoring with a 5 kHz sampling rate. Experimental results demonstrate a correlation coefficient of 0.65 between predicted and actual systolic blood pressure, with a standard error of 4 mmHg. Compared to traditional sensing devices, this FBG-based system is more compact, offers higher resolution, and provides faster response times.

Good health and well-being
Openalex Percentile: Top 34%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High resolution wearable FBG-based sensing device for cardiac rate and blood pressure monitoring — Shuda Zhong, Kevin P. Chen, et al. · (2025) | TGRS Research Map | TGRS