[MEP-26] Safety and Efficacy of Endovascular Repair Using Multilayer Flow Modulators for Thoracic Aortic Aneurysms After Type 1 Aortic Dissection

Objective: This study aimed to explore the outcomes of thoracic endovascular aortic aneurysm repair (TEVAR) for thoracic aortic aneurysms (TAAs) with or without concurrent endovascular abdominal aneurysm repair (EVAR) using multilayer flow modulator stents. Methods: This study included 23 patients (16 males, 7 females; mean age: 64 years) who underwent acute type 1 ascending aortic dissection repair. Symptoms varied from chest and abdominal pain, dyspnea, and fatigue to asymptomatic cases. Multislice computed tomography (CT) angiography assessed all segments of the aorta. We identified TAAs in all patients, with four also having abdominal aneurysms. All patients underwent TEVAR, and EVAR was added when necessary, using a multilayer flow modulator. Control CT angiography was conducted one month after discharge. Results: There were no deaths or major complications. The median interval between primary surgery and CT angiography was 19 months (range, 6 to 60 months). The median hospital stay was 4.2 days. Control angiograms demonstrated 100% technical success with patent aortic lumens and branches. The only complication was a superficial infection in the femoral region. No cases of aortic rupture, stent migration, thrombosis, or stent fracture were observed. One patient had an endoleak at proximal and distal aortic ends, which was addressed with an additional multilayer flow modulator. Conclusion: Thoracic aortic aneurysms with or without abdominal aneurysms should be considered after type I aortic dissection surgery. We recommend it as an effective treatment method because it does not obstruct blood flow in the visceral arteries in patients with complex aortic aneurysms. Further randomized clinical trials are necessary to validate the effectivity of multilayer flow modulator stent.

Authors

Publication Details

Journal
Cardiovascular Surgery and Interventions
Published
2024-11-01
DOI
https://doi.org/10.5606/e-cvsi.2024.mep-26
Primary Topic
Cardiac and Coronary Surgery Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[MEP-26] Safety and Efficacy of Endovascular Repair Using Multilayer Flow Modulators for Thoracic Aortic Aneurysms After Type 1 Aortic Dissection

Murat Kasap, Muhittin Zafer Samsa, Özgür Çoban, Ömer Faruk Doğan
Cardiovascular Surgery and Interventions
Cardiac and Coronary Surgery Techniques
article

[MEP-26] Safety and Efficacy of Endovascular Repair Using Multilayer Flow Modulators for Thoracic Aortic Aneurysms After Type 1 Aortic Dissection

Murat Kasap, Muhittin Zafer Samsa, Özgür Çoban, Ömer Faruk Doğan
article en

Abstract

Objective: This study aimed to explore the outcomes of thoracic endovascular aortic aneurysm repair (TEVAR) for thoracic aortic aneurysms (TAAs) with or without concurrent endovascular abdominal aneurysm repair (EVAR) using multilayer flow modulator stents. Methods: This study included 23 patients (16 males, 7 females; mean age: 64 years) who underwent acute type 1 ascending aortic dissection repair. Symptoms varied from chest and abdominal pain, dyspnea, and fatigue to asymptomatic cases. Multislice computed tomography (CT) angiography assessed all segments of the aorta. We identified TAAs in all patients, with four also having abdominal aneurysms. All patients underwent TEVAR, and EVAR was added when necessary, using a multilayer flow modulator. Control CT angiography was conducted one month after discharge. Results: There were no deaths or major complications. The median interval between primary surgery and CT angiography was 19 months (range, 6 to 60 months). The median hospital stay was 4.2 days. Control angiograms demonstrated 100% technical success with patent aortic lumens and branches. The only complication was a superficial infection in the femoral region. No cases of aortic rupture, stent migration, thrombosis, or stent fracture were observed. One patient had an endoleak at proximal and distal aortic ends, which was addressed with an additional multilayer flow modulator. Conclusion: Thoracic aortic aneurysms with or without abdominal aneurysms should be considered after type I aortic dissection surgery. We recommend it as an effective treatment method because it does not obstruct blood flow in the visceral arteries in patients with complex aortic aneurysms. Further randomized clinical trials are necessary to validate the effectivity of multilayer flow modulator stent.

Cardiovascular Surgery and InterventionsVol. 11(100)
Openalex Percentile: Top 53%
Cardiac and Coronary Surgery Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

[MEP-26] Safety and Efficacy of Endovascular Repair Using Multilayer Flow Modulators for Thoracic Aortic Aneurysms After Type 1 Aortic Dissection — Murat Kasap, Muhittin Zafer Samsa, et al. · Cardiovascular Surgery and Interventions (2024) | TGRS Research Map | TGRS