[MSB-17] Novel “DR MÇ” Technique for the Distal Anastomosis of Hemiarc Replacement Surgery for Acute Type A Aortic Dissection

Objective: This study aimed to define a novel technique to ensure the safety of distal anastomosis in acute type A aortic dissection, a condition with many possible complications. Methods: The “DR MÇ” technique consisted of two components: reinforcing the wall of the dissected aorta and aorta-graft diameter matching. The first technique was applied in our clinic, but the second method had not yet been tested. First, a Teflon band was sutured around the outer wall of the aorta, leaving 5 mm of the aorta at the open end to later contribute to hemostasis during anastomosis. Afterward, the graft was sutured to the aorta; however, the sutures were closer to the anastomosis than to the fixing sutures of the Teflon band. This prevented the tearing of the aorta by distributing the axial forces on the aorta and the anastomosis. The adjustment of graft diameter for the aorta was done accordingly; the graft was cut in an oblique pattern, and an extra elliptical piece was sutured to one side of the graft. This method ensured durability (narrowing of the dissected aorta could cause tearing), and the remaining parts of the graft at the outer side of the anastomosis provided extra hemostatic support. Results: Mortality was often caused by bleeding from the suture points covered by the Teflon. In our center, this method was applied in an attempt to provide better results; however, the sample size was insufficient to provide statistically significant results. Conclusion: In acute type A aortic dissection, the endurance of aortic tissues is impaired, and therefore, conventional anastomosis may not be enough for hemostasis. This technique is a safer approach for aortic tissue endurance.

Authors

Publication Details

Journal
Cardiovascular Surgery and Interventions
Published
2024-11-01
DOI
https://doi.org/10.5606/e-cvsi.2024.msb-17
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[MSB-17] Novel “DR MÇ” Technique for the Distal Anastomosis of Hemiarc Replacement Surgery for Acute Type A Aortic Dissection

Muzaffer Çeliksöz, Ayşe Akkuş
1 links
Cardiovascular Surgery and Interventions
Aortic Disease and Treatment Approaches
article

[MSB-17] Novel “DR MÇ” Technique for the Distal Anastomosis of Hemiarc Replacement Surgery for Acute Type A Aortic Dissection

Muzaffer Çeliksöz, Ayşe Akkuş
article en

Abstract

Objective: This study aimed to define a novel technique to ensure the safety of distal anastomosis in acute type A aortic dissection, a condition with many possible complications. Methods: The “DR MÇ” technique consisted of two components: reinforcing the wall of the dissected aorta and aorta-graft diameter matching. The first technique was applied in our clinic, but the second method had not yet been tested. First, a Teflon band was sutured around the outer wall of the aorta, leaving 5 mm of the aorta at the open end to later contribute to hemostasis during anastomosis. Afterward, the graft was sutured to the aorta; however, the sutures were closer to the anastomosis than to the fixing sutures of the Teflon band. This prevented the tearing of the aorta by distributing the axial forces on the aorta and the anastomosis. The adjustment of graft diameter for the aorta was done accordingly; the graft was cut in an oblique pattern, and an extra elliptical piece was sutured to one side of the graft. This method ensured durability (narrowing of the dissected aorta could cause tearing), and the remaining parts of the graft at the outer side of the anastomosis provided extra hemostatic support. Results: Mortality was often caused by bleeding from the suture points covered by the Teflon. In our center, this method was applied in an attempt to provide better results; however, the sample size was insufficient to provide statistically significant results. Conclusion: In acute type A aortic dissection, the endurance of aortic tissues is impaired, and therefore, conventional anastomosis may not be enough for hemostasis. This technique is a safer approach for aortic tissue endurance.

Cardiovascular Surgery and InterventionsVol. 11(100)
Openalex Percentile: Top 55%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.