[MSB-66] Does Balloon Dilatation Increase the Need for A Permanent Pacemaker in Sutureless Aortic Valve Replacement?

Objective: This study aimed to present the results of balloon dilatation in sutureless valves considering the temporary and permanent need for a pacemaker. Methods: Thirty-eight patients (27 females, 11 males; mean age: 69.42±4.85 years; range, 61 to 82 years) who underwent surgical aortic valve replacement with a sutureless aortic valve bioprosthesis between January 2019 and June 2024 and received balloon dilation at 4 atm (standard atmosphere) pressure for 30 sec during the procedure were retrospectively evaluated. Demographic data, preoperative and postoperative echocardiographic data, and postoperative follow-up data of the patients were collected. Results: On preoperative echocardiographic evaluation, the mean aortic root diameter was 20.99±2.24 mm, the ejection fraction was 59.29±9.57%, and the mean preoperative aortic valve gradient was 38.08±7.31 mmHg. Isolated aortic valve replacement was performed in 22 (57.9%) patients, concomitant coronary bypass was performed in 14 (36.8%) patients, and ascending aorta replacement was performed in two (5.3%) patients. A small valve was inserted in six patients, a medium valve in 13 patients, a large valve in 17 patients, and an extra-large valve in two patients. The mean postoperative aortic valve gradient was 11.52±3.36 mmHg. After surgery, three (7.9%) patients were transferred to the intensive care unit with temporary pacemakers. Permanent pacemaker implantation was required in three (7.9%) patients due to complete atrioventricular block. Conclusion: Although the clinical results with sutureless aortic bioprostheses are satisfactory, the use of balloon dilatation increases the need for permanent pacemakers.

Authors

Publication Details

Journal
Cardiovascular Surgery and Interventions
Published
2024-11-01
DOI
https://doi.org/10.5606/e-cvsi.2024.msb-66
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[MSB-66] Does Balloon Dilatation Increase the Need for A Permanent Pacemaker in Sutureless Aortic Valve Replacement?

Serhat Hüseyın, Orkut Güçlü, Adem Reyhancan, Suat Canbaz et al.
Cardiovascular Surgery and Interventions
Cardiac Valve Diseases and Treatments
article

[MSB-66] Does Balloon Dilatation Increase the Need for A Permanent Pacemaker in Sutureless Aortic Valve Replacement?

Serhat Hüseyın, Orkut Güçlü, Adem Reyhancan, Suat Canbaz, Mürsel Büyükadalı, Fadil Shehu
article en

Abstract

Objective: This study aimed to present the results of balloon dilatation in sutureless valves considering the temporary and permanent need for a pacemaker. Methods: Thirty-eight patients (27 females, 11 males; mean age: 69.42±4.85 years; range, 61 to 82 years) who underwent surgical aortic valve replacement with a sutureless aortic valve bioprosthesis between January 2019 and June 2024 and received balloon dilation at 4 atm (standard atmosphere) pressure for 30 sec during the procedure were retrospectively evaluated. Demographic data, preoperative and postoperative echocardiographic data, and postoperative follow-up data of the patients were collected. Results: On preoperative echocardiographic evaluation, the mean aortic root diameter was 20.99±2.24 mm, the ejection fraction was 59.29±9.57%, and the mean preoperative aortic valve gradient was 38.08±7.31 mmHg. Isolated aortic valve replacement was performed in 22 (57.9%) patients, concomitant coronary bypass was performed in 14 (36.8%) patients, and ascending aorta replacement was performed in two (5.3%) patients. A small valve was inserted in six patients, a medium valve in 13 patients, a large valve in 17 patients, and an extra-large valve in two patients. The mean postoperative aortic valve gradient was 11.52±3.36 mmHg. After surgery, three (7.9%) patients were transferred to the intensive care unit with temporary pacemakers. Permanent pacemaker implantation was required in three (7.9%) patients due to complete atrioventricular block. Conclusion: Although the clinical results with sutureless aortic bioprostheses are satisfactory, the use of balloon dilatation increases the need for permanent pacemakers.

Cardiovascular Surgery and InterventionsVol. 11(100)
Openalex Percentile: Top 53%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.