[MSB-64] Heartmate 3 In Heart Failure Treatment: Initial Experience of A Newly Established Mechanical Circulatory Support and Heart Transplantation Center

Objective: This study aimed to share our experience with HeartMate 3 (HM3), a ventricular assist device. Methods: Seven male patients with the diagnosis of end-stage heart failure underwent HM3 implantation between August 2023 and August 2024. Three patients were INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) Stage 1 (42.8%), three patients were INTERMACS Stage 2 (42.8%), and one patient was INTERMACS Stage 3 (14.2%). A bridge to transplant was aimed in 71% of patients, with the rest being destination therapy. One patient underwent reexploration in the early postoperative period due to hemorrhage. Warfarin sodium and acetylsalicylic acid were given for anticoagulation and antiaggregation therapy, with a target INR (international normalized ratio) between 2.5 and 3.0. Results: Overall support time was between 230 and 395 days, with a mean of 253 days. Two patients developed acute renal failure during the early postoperative period. One patient underwent mediastinal exploration during the early postoperative period due to hemorrhage. One patient developed an outflow graft thrombosis requiring corrective reoperation. This patient died on the first postoperative day due to an intractable right ventricular failure. The mortality rate was 14.2% in this series. Conclusion: In certain cases with advanced heart failure, patients can be severely impaired and symptomatic despite maximum medical treatment. Since donor organ availability is limited in the current social environment, left ventricular assist device implantation is the only logical option for the treatment of this patient group as a bridge to transplant or destination therapy.

Authors

Publication Details

Journal
Cardiovascular Surgery and Interventions
Published
2024-11-01
DOI
https://doi.org/10.5606/e-cvsi.2024.msb-64
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[MSB-64] Heartmate 3 In Heart Failure Treatment: Initial Experience of A Newly Established Mechanical Circulatory Support and Heart Transplantation Center

Sinan Erkul, Mehmed Yanartaş, Nihan Kayalar, Mehmet Karabulut et al.
1 links
Cardiovascular Surgery and Interventions
Fuel Cells and Related Materials
article

[MSB-64] Heartmate 3 In Heart Failure Treatment: Initial Experience of A Newly Established Mechanical Circulatory Support and Heart Transplantation Center

Sinan Erkul, Mehmed Yanartaş, Nihan Kayalar, Mehmet Karabulut, Gizem Kolay
article en

Abstract

Objective: This study aimed to share our experience with HeartMate 3 (HM3), a ventricular assist device. Methods: Seven male patients with the diagnosis of end-stage heart failure underwent HM3 implantation between August 2023 and August 2024. Three patients were INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) Stage 1 (42.8%), three patients were INTERMACS Stage 2 (42.8%), and one patient was INTERMACS Stage 3 (14.2%). A bridge to transplant was aimed in 71% of patients, with the rest being destination therapy. One patient underwent reexploration in the early postoperative period due to hemorrhage. Warfarin sodium and acetylsalicylic acid were given for anticoagulation and antiaggregation therapy, with a target INR (international normalized ratio) between 2.5 and 3.0. Results: Overall support time was between 230 and 395 days, with a mean of 253 days. Two patients developed acute renal failure during the early postoperative period. One patient underwent mediastinal exploration during the early postoperative period due to hemorrhage. One patient developed an outflow graft thrombosis requiring corrective reoperation. This patient died on the first postoperative day due to an intractable right ventricular failure. The mortality rate was 14.2% in this series. Conclusion: In certain cases with advanced heart failure, patients can be severely impaired and symptomatic despite maximum medical treatment. Since donor organ availability is limited in the current social environment, left ventricular assist device implantation is the only logical option for the treatment of this patient group as a bridge to transplant or destination therapy.

Cardiovascular Surgery and InterventionsVol. 11(100)
Openalex Percentile: Top 74%
Fuel Cells and Related Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

[MSB-64] Heartmate 3 In Heart Failure Treatment: Initial Experience of A Newly Established Mechanical Circulatory Support and Heart Transplantation Center — Sinan Erkul, Mehmed Yanartaş, et al. · Cardiovascular Surgery and Interventions (2024) | TGRS Research Map | TGRS