Coupled cantilever biosensor utilizing a novel approach to gap-method for real-time detection of E. coli in low concentrations

Biosensors have become indispensable for rapid detection of pathogens and play a vital role in the monitoring of bioparticles in healthcare, environmental monitoring and food safety. This paper presents a novel microsensor consisting of a pair of coupled cantilevers. During testing, the cantilevers are immersed in a sample solution and one of the cantilevers is actively actuated to vibrate while the other is passively driven through the sample solution. To accelerate pathogen capture, dielectrophoresis (DEP) is used to concentrate the sparse bacteria in the sample solution to the gap region between the cantilevers. The captured bacteria cause frequency shifts for both cantilevers. The limit of detection (LOD) of the sensor is determined to be 15 cells/ml and signal-to-noise ratio (SNR) reaches to 12.8 and higher. For stagnant samples, high frequency shifts of up to 3.1 kHz are observed for 10 5 cells/ml while even for a low concentration of 100 cells/ml a substantial frequency shift of 914 Hz is recorded. Performance is also characterized at different flowrates, and significant frequency shifts up to 1.7 kHz are observed for 10 5 cells/ml concentration at 1 µl/min. These advancements establish the proposed biosensor as a highly sensitive, and versatile tool for detecting pathogens in diverse applications. • A novel biosensor using two coupled microcantilevers is presented. • The two microcantilevers are coupled through pathogens to be detected. • Pathogens are rapidly attracted to the specified area using DEP. • High SNR and low LOD are achieved. • Real-time testing using stagnant and flowing samples is conducted.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2025-03-20
DOI
https://doi.org/10.1016/j.snb.2025.137665
Citations
3
Primary Topic
Mechanical and Optical Resonators
Type
article
Field-Weighted Citation Impact
3.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coupled cantilever biosensor utilizing a novel approach to gap-method for real-time detection of E. coli in low concentrations

Syed Bukhari, Yongjun Lai, Elham Alaei
3 citations
Sensors and Actuators B Chemical
Mechanical and Optical Resonators
3.74
article

Coupled cantilever biosensor utilizing a novel approach to gap-method for real-time detection of E. coli in low concentrations

Syed Bukhari, Yongjun Lai, Elham Alaei
article en
3 citations

Abstract

Biosensors have become indispensable for rapid detection of pathogens and play a vital role in the monitoring of bioparticles in healthcare, environmental monitoring and food safety. This paper presents a novel microsensor consisting of a pair of coupled cantilevers. During testing, the cantilevers are immersed in a sample solution and one of the cantilevers is actively actuated to vibrate while the other is passively driven through the sample solution. To accelerate pathogen capture, dielectrophoresis (DEP) is used to concentrate the sparse bacteria in the sample solution to the gap region between the cantilevers. The captured bacteria cause frequency shifts for both cantilevers. The limit of detection (LOD) of the sensor is determined to be 15 cells/ml and signal-to-noise ratio (SNR) reaches to 12.8 and higher. For stagnant samples, high frequency shifts of up to 3.1 kHz are observed for 10 5 cells/ml while even for a low concentration of 100 cells/ml a substantial frequency shift of 914 Hz is recorded. Performance is also characterized at different flowrates, and significant frequency shifts up to 1.7 kHz are observed for 10 5 cells/ml concentration at 1 µl/min. These advancements establish the proposed biosensor as a highly sensitive, and versatile tool for detecting pathogens in diverse applications. • A novel biosensor using two coupled microcantilevers is presented. • The two microcantilevers are coupled through pathogens to be detected. • Pathogens are rapidly attracted to the specified area using DEP. • High SNR and low LOD are achieved. • Real-time testing using stagnant and flowing samples is conducted.

Sensors and Actuators B ChemicalVol. 435
Queen's University (CA)
Natural Sciences and Engineering Research Council of Canada
Affordable and clean energy
Openalex Percentile: Top 8%
Mechanical and Optical Resonators
3.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Coupled cantilever biosensor utilizing a novel approach to gap-method for real-time detection of E. coli in low concentrations — Syed Bukhari, Yongjun Lai, et al. · Sensors and Actuators B Chemical (2025) | TGRS Research Map | TGRS