Whispering gallery mode laser: towards the deep and turbid tissue optical sensing

This study explores the application of whispering gallery mode (WGM) lasers for deep optical sensing in turbid media. Experimental results demonstrate that WGM lasers achieve accurate detection of the resonator diameter when it is deep in a highly scattering medium. Specifically, a resonator diameter of 261 &mu;m is detectable with low intra-sample variation (&lt;&plusmn;2&percnt;), even when the resonator is placed at 5 mm deep in a scattering medium with a reduced scattering coefficient of 6.3 mm<sup>−1</sup> , a value comparable to the reduced scattering coefficient of skin tissues in visible range. In other words, the sample depth exceeds 30 times the transport length while the resolution maintains in micrometer range. As a comparison, the conventional method of optical coherence tomography can only achieve the penetration depth of one transport length.

Authors

Publication Details

Published
2025-03-20
DOI
https://doi.org/10.1117/12.3041234
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Whispering gallery mode laser: towards the deep and turbid tissue optical sensing

Michael Schmidt, Martin Hohmann, Florian Klämpfl, Dongqin Ni
Optical Coherence Tomography Applications
article

Whispering gallery mode laser: towards the deep and turbid tissue optical sensing

Michael Schmidt, Martin Hohmann, Florian Klämpfl, Dongqin Ni
article en

Abstract

This study explores the application of whispering gallery mode (WGM) lasers for deep optical sensing in turbid media. Experimental results demonstrate that WGM lasers achieve accurate detection of the resonator diameter when it is deep in a highly scattering medium. Specifically, a resonator diameter of 261 &mu;m is detectable with low intra-sample variation (&lt;&plusmn;2&percnt;), even when the resonator is placed at 5 mm deep in a scattering medium with a reduced scattering coefficient of 6.3 mm<sup>−1</sup> , a value comparable to the reduced scattering coefficient of skin tissues in visible range. In other words, the sample depth exceeds 30 times the transport length while the resolution maintains in micrometer range. As a comparison, the conventional method of optical coherence tomography can only achieve the penetration depth of one transport length.

Climate action
Openalex Percentile: Top 95%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.