A smartphone-based NIRS optical imaging device (SPOT – smartphone-based oxygenation tool) was developed to evaluate hemoglobin-based tissue oxygenation maps toward wound healing applications. Diffuse reflectance (690, 810, and 830 nm) on the wound is recorded and used to generate tissue oxygenation maps using modified Beer-Lambert’s lawbased light propagation model. However, the skin surrounding the wound contains melanin, which is a significant absorber in the NIR range. It largely affects the acquired diffuse reflectance and eventually the tissue oxygenation measurements. Hence, the objective of this study was to develop a melanin correction factor and validate via phantom studies. For the melanin correction factor, Monte Carlo-based light propagation simulations on a two-layer skin model (x-4cm, y-4cm, epidermis: z-2mm, dermis: z-30mm), at SPOT's wavelengths (690, 810, 830 nm) were conducted. The epidermal melanin volume fraction was varied to achieve absorption coefficients (690nm: 0.29-100.2 𝑐𝑚<sup>−1</sup>, 810nm: 0.17-58.8 𝑐𝑚<sup>−1</sup>, 830nm: 0.16-54.2 𝑐𝑚<sup>−1</sup>representative of the Fitzpatrick skin types. The melanin correction factor was developed for each wavelength separately. The sensitivity of the correction factor (at each respective wavelength) was evaluated by varying the epidermal thickness (0.015-0.55cm) and varying the dermal optical properties (690nm: 0.12-1.53 𝑐𝑚<sup>−1</sup>, 810nm: 0.02- 1.22 𝑐𝑚<sup>−1</sup>, 830nm: 0.32-0.83 𝑐𝑚<sup>−1</sup> for each FST. Across the wavelengths, the melanin correction factors for each FST showed a low variation when epidermal thickness (&lt;1.5%) and dermal optical properties (&lt;5%) were varied. Ongoing validation studies include developing and standardizing agar-based two-layered phantoms of different FSTs. This will be followed by imaging studies using SPOT on the phantoms and applying the correction factor to evaluate the accuracy of tissue oxygenation measurements.

Authors

Institutions

Publication Details

Published
2025-03-20
DOI
https://doi.org/10.1117/12.3043295
Primary Topic
melanin and skin pigmentation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of a melanin correction factor for a smartphone-based NIRS optical imaging device

Douglas A. Campbell, Anuradha Godavarty, Daniela Leizaola, María Hernández
melanin and skin pigmentation
article

Development and validation of a melanin correction factor for a smartphone-based NIRS optical imaging device

Douglas A. Campbell, Anuradha Godavarty, Daniela Leizaola, María Hernández
article en

Abstract

A smartphone-based NIRS optical imaging device (SPOT – smartphone-based oxygenation tool) was developed to evaluate hemoglobin-based tissue oxygenation maps toward wound healing applications. Diffuse reflectance (690, 810, and 830 nm) on the wound is recorded and used to generate tissue oxygenation maps using modified Beer-Lambert’s lawbased light propagation model. However, the skin surrounding the wound contains melanin, which is a significant absorber in the NIR range. It largely affects the acquired diffuse reflectance and eventually the tissue oxygenation measurements. Hence, the objective of this study was to develop a melanin correction factor and validate via phantom studies. For the melanin correction factor, Monte Carlo-based light propagation simulations on a two-layer skin model (x-4cm, y-4cm, epidermis: z-2mm, dermis: z-30mm), at SPOT's wavelengths (690, 810, 830 nm) were conducted. The epidermal melanin volume fraction was varied to achieve absorption coefficients (690nm: 0.29-100.2 𝑐𝑚<sup>−1</sup>, 810nm: 0.17-58.8 𝑐𝑚<sup>−1</sup>, 830nm: 0.16-54.2 𝑐𝑚<sup>−1</sup>representative of the Fitzpatrick skin types. The melanin correction factor was developed for each wavelength separately. The sensitivity of the correction factor (at each respective wavelength) was evaluated by varying the epidermal thickness (0.015-0.55cm) and varying the dermal optical properties (690nm: 0.12-1.53 𝑐𝑚<sup>−1</sup>, 810nm: 0.02- 1.22 𝑐𝑚<sup>−1</sup>, 830nm: 0.32-0.83 𝑐𝑚<sup>−1</sup> for each FST. Across the wavelengths, the melanin correction factors for each FST showed a low variation when epidermal thickness (&lt;1.5%) and dermal optical properties (&lt;5%) were varied. Ongoing validation studies include developing and standardizing agar-based two-layered phantoms of different FSTs. This will be followed by imaging studies using SPOT on the phantoms and applying the correction factor to evaluate the accuracy of tissue oxygenation measurements.

Florida International University (US)
Openalex Percentile: Top 94%
melanin and skin pigmentation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.