Wearable monitor for the assessment of tissue water fraction as a marker of edema development (Conference Presentation)

Peripheral edema occurs due to various causes including inflammation, injury or cardiovascular diseases. Importantly, it is a marker of decompensation in patients with heart failure. Timely detection of edema development prior to overt symptom development requires continuous monitoring. We are developing a multi-wavelength wearable derived from the previously demonstrated FlexNIRS platform to assess the tissue water fraction. We show validation measurements of discrete wavelength, multi-distance CW-NIRS measurements against frequency-domain NIRS and broadband spectroscopy using both a subset of the spectrometer measurements and a custom multi-wavelength LED module based wearable prototype. Results are reported from both phantoms and in vivo measurements.

Authors

Institutions

Publication Details

Published
2025-03-20
DOI
https://doi.org/10.1117/12.3043393
Primary Topic
Body Composition Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable monitor for the assessment of tissue water fraction as a marker of edema development (Conference Presentation)

Nikola Otic, Marco Renna, Maria Angela Franceschini, Mitchell B. Robinson et al.
Body Composition Measurement Techniques
article

Wearable monitor for the assessment of tissue water fraction as a marker of edema development (Conference Presentation)

Nikola Otic, Marco Renna, Maria Angela Franceschini, Mitchell B. Robinson, Kuan-Cheng Wu, Stefan A. Carp, Ailis Muldoon, Shakeeb Habash, So Hyun Chung
article en

Abstract

Peripheral edema occurs due to various causes including inflammation, injury or cardiovascular diseases. Importantly, it is a marker of decompensation in patients with heart failure. Timely detection of edema development prior to overt symptom development requires continuous monitoring. We are developing a multi-wavelength wearable derived from the previously demonstrated FlexNIRS platform to assess the tissue water fraction. We show validation measurements of discrete wavelength, multi-distance CW-NIRS measurements against frequency-domain NIRS and broadband spectroscopy using both a subset of the spectrometer measurements and a custom multi-wavelength LED module based wearable prototype. Results are reported from both phantoms and in vivo measurements.

Harvard University (US), Massachusetts General Hospital (US)
Clean water and sanitation
Openalex Percentile: Top 93%
Body Composition Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.