Preliminary investigation of partial optical path-lengths in pulse oximetry

Pulse oximetry, a ubiquitous method for determining a person’s oxygen delivery, has recently been criticized for its possible inaccuracy and bias, especially in cases of low oxygen saturation or darker skin tones. Typical pulse oximetry methods utilize an empirical calibration, which may lead to these issues. Alternatively, expressions to compute arterial oxygen saturation from pulsatile optical signals can be derived based on modified Beer-Lambert law. The key known parameter in the modified Beer-Lambert law expression is the ratio of optical path-lengths at infrared and red wavelengths. In this work we utilized a simple Monte Carlo model to investigate this ratio of path-lengths. The results suggest that the path length in the annulus surrounding blood vessels is what should be considered in the modified Beer-Lambert law derived expression. Furthermore, since our preliminary results show that this ratio of path-lengths depends on oxygen saturation, the linearity assumptions of modified Beer-Lambert law may not be valid for pulse oximetry. Future work will utilize the model herein to further investigate what parameters and considerations are important to pulse oximetry.

Authors

Publication Details

Published
2025-03-20
DOI
https://doi.org/10.1117/12.3042282
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preliminary investigation of partial optical path-lengths in pulse oximetry

Fatemeh Tavakoli, Angelo Sassaroli, Giles Blaney, Sergio Fantini et al.
Spectroscopy and Laser Applications
article

Preliminary investigation of partial optical path-lengths in pulse oximetry

Fatemeh Tavakoli, Angelo Sassaroli, Giles Blaney, Sergio Fantini, Jodee Frias
article en

Abstract

Pulse oximetry, a ubiquitous method for determining a person’s oxygen delivery, has recently been criticized for its possible inaccuracy and bias, especially in cases of low oxygen saturation or darker skin tones. Typical pulse oximetry methods utilize an empirical calibration, which may lead to these issues. Alternatively, expressions to compute arterial oxygen saturation from pulsatile optical signals can be derived based on modified Beer-Lambert law. The key known parameter in the modified Beer-Lambert law expression is the ratio of optical path-lengths at infrared and red wavelengths. In this work we utilized a simple Monte Carlo model to investigate this ratio of path-lengths. The results suggest that the path length in the annulus surrounding blood vessels is what should be considered in the modified Beer-Lambert law derived expression. Furthermore, since our preliminary results show that this ratio of path-lengths depends on oxygen saturation, the linearity assumptions of modified Beer-Lambert law may not be valid for pulse oximetry. Future work will utilize the model herein to further investigate what parameters and considerations are important to pulse oximetry.

Openalex Percentile: Top 95%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Preliminary investigation of partial optical path-lengths in pulse oximetry — Fatemeh Tavakoli, Angelo Sassaroli, et al. · (2025) | TGRS Research Map | TGRS