Supervised IR-laser-based bone surgery for stenosis decompression

People who suffer from spinal stenosis can experience severe pain and mobility restrictions. The conventional surgical method using a surgical burr carries the risk of damaging underlying spinal cord tissue due to missing depth control, leading to prolonged operation times and recovery periods. A laser handpiece in combination with optical coherence tomography (OCT) can achieve higher precision in stenosis decompression. We conducted a parameter study with 2 μm and 3 μm wavelength lasers to compare ablation depth to laser power, pulse duration and bone hydration. A thermographic camera was used to monitor the temperature of the tissue surrounding the laser focus to adjust the parameters for water spray cooling and ensure that the biological damage threshold of 47°C for one minute was never exceeded. The OCT signal is used to detect underlying tissues to avoid damage. The aim of the research is to combine all techniques in one endoscopic device.

Authors

Institutions

Publication Details

Published
2025-03-20
DOI
https://doi.org/10.1117/12.3040693
Primary Topic
Laser Applications in Dentistry and Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Supervised IR-laser-based bone surgery for stenosis decompression

Tammo Ripken, Jaryi Lippek, Sonja Johannsmeier, M. E. Müller et al.
Laser Applications in Dentistry and Medicine
article

Supervised IR-laser-based bone surgery for stenosis decompression

Tammo Ripken, Jaryi Lippek, Sonja Johannsmeier, M. E. Müller, Björn Spoida, Tilman Barke
article en

Abstract

People who suffer from spinal stenosis can experience severe pain and mobility restrictions. The conventional surgical method using a surgical burr carries the risk of damaging underlying spinal cord tissue due to missing depth control, leading to prolonged operation times and recovery periods. A laser handpiece in combination with optical coherence tomography (OCT) can achieve higher precision in stenosis decompression. We conducted a parameter study with 2 μm and 3 μm wavelength lasers to compare ablation depth to laser power, pulse duration and bone hydration. A thermographic camera was used to monitor the temperature of the tissue surrounding the laser focus to adjust the parameters for water spray cooling and ensure that the biological damage threshold of 47°C for one minute was never exceeded. The OCT signal is used to detect underlying tissues to avoid damage. The aim of the research is to combine all techniques in one endoscopic device.

Laser Zentrum Hannover (DE), K-Implant (Germany) (DE)
Openalex Percentile: Top 92%
Laser Applications in Dentistry and Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.