Advancing the detection threshold of fluorescence lifetime correlation spectroscopy (FLCS) to the sub-picomolar level

Fluorescence lifetime correlation spectroscopy (FLCS) uses lifetime information to distinguish different species within a mixture and remove background and after-pulsing artifacts in regular FCS. However, there is little documentation regarding the sensitivity of this technique to obtain reliable data at low fluorophore concentrations in the sub-picomolar range, which is crucial for detecting trace amounts of biomarkers. Our goal is to figure out the physical parameters that determine the limit of detection of FLCS and design the best-performing microscope setup by finding the best compromise between fluorescence brightness and detection volume. Our approach could push the detection limit of FLCS to sub picomolar range. We apply this to study biotin-streptavidin kinetics which is of utmost importance for biotechnologies but is difficult to measure due to its ultra-high affinity.

Authors

Institutions

Publication Details

Published
2025-03-19
DOI
https://doi.org/10.1117/12.3039025
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advancing the detection threshold of fluorescence lifetime correlation spectroscopy (FLCS) to the sub-picomolar level

Jérôme Wenger, Malavika Kayyil Veedu
Spectroscopy and Laser Applications
article

Advancing the detection threshold of fluorescence lifetime correlation spectroscopy (FLCS) to the sub-picomolar level

Jérôme Wenger, Malavika Kayyil Veedu
article en

Abstract

Fluorescence lifetime correlation spectroscopy (FLCS) uses lifetime information to distinguish different species within a mixture and remove background and after-pulsing artifacts in regular FCS. However, there is little documentation regarding the sensitivity of this technique to obtain reliable data at low fluorophore concentrations in the sub-picomolar range, which is crucial for detecting trace amounts of biomarkers. Our goal is to figure out the physical parameters that determine the limit of detection of FLCS and design the best-performing microscope setup by finding the best compromise between fluorescence brightness and detection volume. Our approach could push the detection limit of FLCS to sub picomolar range. We apply this to study biotin-streptavidin kinetics which is of utmost importance for biotechnologies but is difficult to measure due to its ultra-high affinity.

Centre National de la Recherche Scientifique (FR), Institut de Microbiologie de la Méditerranée (FR), Institut de Neurobiologie de la Méditerranée (FR), Institut Fresnel (FR), Centrale Méditerranée (FR)
Openalex Percentile: Top 95%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.