Abstract This paper introduces a high-precision and nearly single-pixel three-dimensional (3D) calibration framework for the camera system and optical transfer function (OTF); using a digital micromirror device (DMD) to generate a large number of 3D calibration points, precise 3D reconstruction and 2D reprojection for particle-based velocimetry techniques is achieved. Additionally, a line-of-sight (LOS) calibration approach, which utilizes an extensive number of LOSs from 3D points to 2D centers, leverages accurate 2D reprojection and 3D reconstruction—even in the presence of curved interfaces with significant refractive index variations. In camera calibration, the high-frequency DMD can efficiently generate 240 000 3D volume points for a single Z -plane at −15 mm or +15 mm, which can be captured by a 400 Hz camera in just 6.25 s; as well as a massive dataset of 3072 000 calibration points in 80 planes can be obtained quickly. This extensive calibration dataset defining projection of 3D to 2D points enhances the performance of both pinhole Tsai camera model and polynomial model in the presence of a planar refractive interface. As for the planar or curved refractive interfaces, such LOS calibration proves to be more effective, significantly improving 3D reconstruction and 2D reprojection accuracy compared to the pinhole Tsai camera and polynomial models. Using this large calibration dataset, the averaging OTF strategy (with a reprojection similarity of about 0.92) is feasible for efficiency-first measurement applications, as a coarser OTF grid enhances computational efficiency. While the higher resolution OTF grid can further improve projection quality (maximal similarity of over 0.94) through interpolation from the OTF grid. This strategy is highly beneficial for 2D reprojection in simultaneous multiplicative algebraic reconstruction techniques or iterative particle reconstruction procedures, ultimately leading to improved 3D reconstruction in particle-based velocimetry techniques.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2025-03-20
DOI
https://doi.org/10.1088/1361-6501/adc322
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digital micromirror device enriched nearly single-pixel 3D calibration framework for particle-based velocimetry techniques

Xin Wen, Benlong Wang, Di Peng, Yingzheng Liu et al.
Measurement Science and Technology
Optical measurement and interference techniques
article

Digital micromirror device enriched nearly single-pixel 3D calibration framework for particle-based velocimetry techniques

Xin Wen, Benlong Wang, Di Peng, Yingzheng Liu, Xin Zeng, J. Cao
article en

Abstract

Abstract This paper introduces a high-precision and nearly single-pixel three-dimensional (3D) calibration framework for the camera system and optical transfer function (OTF); using a digital micromirror device (DMD) to generate a large number of 3D calibration points, precise 3D reconstruction and 2D reprojection for particle-based velocimetry techniques is achieved. Additionally, a line-of-sight (LOS) calibration approach, which utilizes an extensive number of LOSs from 3D points to 2D centers, leverages accurate 2D reprojection and 3D reconstruction—even in the presence of curved interfaces with significant refractive index variations. In camera calibration, the high-frequency DMD can efficiently generate 240 000 3D volume points for a single Z -plane at −15 mm or +15 mm, which can be captured by a 400 Hz camera in just 6.25 s; as well as a massive dataset of 3072 000 calibration points in 80 planes can be obtained quickly. This extensive calibration dataset defining projection of 3D to 2D points enhances the performance of both pinhole Tsai camera model and polynomial model in the presence of a planar refractive interface. As for the planar or curved refractive interfaces, such LOS calibration proves to be more effective, significantly improving 3D reconstruction and 2D reprojection accuracy compared to the pinhole Tsai camera and polynomial models. Using this large calibration dataset, the averaging OTF strategy (with a reprojection similarity of about 0.92) is feasible for efficiency-first measurement applications, as a coarser OTF grid enhances computational efficiency. While the higher resolution OTF grid can further improve projection quality (maximal similarity of over 0.94) through interpolation from the OTF grid. This strategy is highly beneficial for 2D reprojection in simultaneous multiplicative algebraic reconstruction techniques or iterative particle reconstruction procedures, ultimately leading to improved 3D reconstruction in particle-based velocimetry techniques.

Measurement Science and TechnologyVol. 36(4)
Shanghai Jiao Tong University (CN), Shanghai Ocean University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 96%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.