A Non-Enzymatic Electrochemical Uric Acid Sensor Based on a Screen-Printed Electrode Modified with a Photopolymerized Molecularly Imprinted Polymer Membrane

A non-enzymatic sensor for uric acid detection based on an electro-transducer has been developed using screen-printed electrode-modified molecularly imprinted polymer (SPE-MIPs). The MIPs have been synthesized from uric acid (template), methacrylic acid/MAA (monomer), and ethylene glycol dimethacrylate/EGDMA (crosslinker) by photopolymerization procedure. The differential pulse voltammetry (DPV) method was used to test the uric acid sensor response. The linear response range of the uric acid electrochemical sensor was obtained from 0.595 to 356.905 μmoll −1 (R 2 = 0.99) by DPV with a detection limit of 0.452 μmoll −1 at pH 7.0. In addition, the sensor has a sensitivity of −0.0188 μA/μmoll −1 . The uric acid extraction time is 30 min, while the uric acid re-extraction time is 14 min. The voltammetric uric acid sensor response showed good reproducibility with a promising relative standard deviation acquired at 5.643% ( n = 9). The ultra-high sensitivity performance of the developed uric acid sensor based on MAA and EGDMA molecularly imprinted polymer towards determining uric acid concentrations at low levels has demonstrated superior performance across previously reported electrochemical uric acid sensors based on various MIPs.

Authors

Publication Details

Journal
Journal of The Electrochemical Society
Published
2025-03-01
DOI
https://doi.org/10.1149/1945-7111/adc342
Citations
2
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Non-Enzymatic Electrochemical Uric Acid Sensor Based on a Screen-Printed Electrode Modified with a Photopolymerized Molecularly Imprinted Polymer Membrane

Jaafar Abdullah, Alizar Ulianas, Sharina Abu Hanifah, Riyadh Abdulmalek Hassan et al.
2 citations
Journal of The Electrochemical Society
Advanced Chemical Sensor Technologies
1.35
article

A Non-Enzymatic Electrochemical Uric Acid Sensor Based on a Screen-Printed Electrode Modified with a Photopolymerized Molecularly Imprinted Polymer Membrane

Jaafar Abdullah, Alizar Ulianas, Sharina Abu Hanifah, Riyadh Abdulmalek Hassan, Desy Kurniawati, Syamsi Aini
article en
2 citations

Abstract

A non-enzymatic sensor for uric acid detection based on an electro-transducer has been developed using screen-printed electrode-modified molecularly imprinted polymer (SPE-MIPs). The MIPs have been synthesized from uric acid (template), methacrylic acid/MAA (monomer), and ethylene glycol dimethacrylate/EGDMA (crosslinker) by photopolymerization procedure. The differential pulse voltammetry (DPV) method was used to test the uric acid sensor response. The linear response range of the uric acid electrochemical sensor was obtained from 0.595 to 356.905 μmoll −1 (R 2 = 0.99) by DPV with a detection limit of 0.452 μmoll −1 at pH 7.0. In addition, the sensor has a sensitivity of −0.0188 μA/μmoll −1 . The uric acid extraction time is 30 min, while the uric acid re-extraction time is 14 min. The voltammetric uric acid sensor response showed good reproducibility with a promising relative standard deviation acquired at 5.643% ( n = 9). The ultra-high sensitivity performance of the developed uric acid sensor based on MAA and EGDMA molecularly imprinted polymer towards determining uric acid concentrations at low levels has demonstrated superior performance across previously reported electrochemical uric acid sensors based on various MIPs.

Journal of The Electrochemical SocietyVol. 172(3)
Openalex Percentile: Top 21%
Advanced Chemical Sensor Technologies
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.