Evaluation of early implant failure in Japanese patients undergoing unrestricted kinematic alignment total knee arthroplasty

Total knee arthroplasty (TKA) traditionally involves mechanical alignment with a target range of ±3°. However, unrestricted kinematic alignment (urKA) has emerged as a viable alternative, potentially maintaining a favorable implant survival rate without the constraints of neutral alignment. Japanese people have more pronounced tibial varus than other populations. This study evaluated early implant failures in Japanese patients with osteoarthritis who underwent urKA-TKA. In this study, 557 knees of 460 patients who underwent urKA-TKA between June 2019 and September 2021 were retrospectively analyzed. Surgeries were conducted by four surgeons using standardized urKA techniques, ensuring consistent ligament balancing and component positioning. The primary outcome was the rate of revision for aseptic loosening over at least 2 years, with secondary outcomes focusing on post-operative alignment. The follow-up rate was 95%, with a mean of 3.0 years. The implant survival rate was 100% considering implant revision as the endpoint, and 99% when re-operation was included. Post-operative alignment revealed that 60.3% of tibial components and 39.3% of limbs had varus alignment exceeding 3°; however, this did not compromise implant survival during the follow-up period. The follow-up of at least 2 years for urKA-TKA in a Japanese cohort demonstrated no early implant failures with no significant effect on outcomes from deviations in varus alignment. These results support the use of urKA-TKA and underscore the need for long-term studies to further substantiate these findings in the Japanese population. • Total knee arthroplasty (TKA) traditionally involves mechanical neutral alignment. • Unrestricted kinematic alignment (urKA) has emerged as a potential viable alternative. • Study of Japanese patients with osteoarthritis undergoing urKA-TKA. • No early implant failures were found. • The study supports the use of urKA-TKA.

Authors

Institutions

Publication Details

Journal
Journal of Joint Surgery and Research
Published
2025-03-20
DOI
https://doi.org/10.1016/j.jjoisr.2025.02.004
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of early implant failure in Japanese patients undergoing unrestricted kinematic alignment total knee arthroplasty

Michiaki Takagi, Shuji Toyono, Takahiro Miyaji, Takao Yamamoto et al.
Journal of Joint Surgery and Research
Total Knee Arthroplasty Outcomes
article

Evaluation of early implant failure in Japanese patients undergoing unrestricted kinematic alignment total knee arthroplasty

Michiaki Takagi, Shuji Toyono, Takahiro Miyaji, Takao Yamamoto, Takashi Ito, Akemi Suzuki, Shigenobu Fukushima
article en

Abstract

Total knee arthroplasty (TKA) traditionally involves mechanical alignment with a target range of ±3°. However, unrestricted kinematic alignment (urKA) has emerged as a viable alternative, potentially maintaining a favorable implant survival rate without the constraints of neutral alignment. Japanese people have more pronounced tibial varus than other populations. This study evaluated early implant failures in Japanese patients with osteoarthritis who underwent urKA-TKA. In this study, 557 knees of 460 patients who underwent urKA-TKA between June 2019 and September 2021 were retrospectively analyzed. Surgeries were conducted by four surgeons using standardized urKA techniques, ensuring consistent ligament balancing and component positioning. The primary outcome was the rate of revision for aseptic loosening over at least 2 years, with secondary outcomes focusing on post-operative alignment. The follow-up rate was 95%, with a mean of 3.0 years. The implant survival rate was 100% considering implant revision as the endpoint, and 99% when re-operation was included. Post-operative alignment revealed that 60.3% of tibial components and 39.3% of limbs had varus alignment exceeding 3°; however, this did not compromise implant survival during the follow-up period. The follow-up of at least 2 years for urKA-TKA in a Japanese cohort demonstrated no early implant failures with no significant effect on outcomes from deviations in varus alignment. These results support the use of urKA-TKA and underscore the need for long-term studies to further substantiate these findings in the Japanese population. • Total knee arthroplasty (TKA) traditionally involves mechanical neutral alignment. • Unrestricted kinematic alignment (urKA) has emerged as a potential viable alternative. • Study of Japanese patients with osteoarthritis undergoing urKA-TKA. • No early implant failures were found. • The study supports the use of urKA-TKA.

Journal of Joint Surgery and ResearchVol. 3(2)
Yamagata University (JP), Yamagata City Hospital Saiseikan (JP), Yamagata Prefectural Shinjo Hospital (JP)
Openalex Percentile: Top 91%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.