Ventilation Effectiveness: Overview of Terminology and Analysis of Influencing Parameters

Ventilation effectiveness evaluates the performance of ventilation systems by assessing air exchange and contaminant removal. Optimising ventilation effectiveness in mechanical ventilation systems reduces the required supply airflow rate while maintaining adequate indoor air quality. This review clarifies inconsistent definitions of ventilation effectiveness in standards and literature and provides a comprehensive overview of terms, definitions, and relevant parameters. The review also analyses the influence of variable and building‐fixed parameters on ventilation effectiveness using data from selected studies. Contaminant position and supply/exhaust position had the greatest impact on ventilation effectiveness, with maximum absolute changes of 2.1 and 0.94, respectively. Variable parameters, such as air change rate and temperature difference, showed moderate mean absolute changes of 0.28 and 0.15 but significant maximum deviations of 0.85 and 0.4. Building‐fixed parameters, including room size and aspect ratio, showed the least influence, with mean absolute changes below 0.1. These results highlight the importance of parameter interactions, such as short‐circuit flows caused by higher air velocities. In EN 16798‐1:2022, design values for required airflow are based on a ventilation effectiveness of 1. However, the analysis shows large variations around this value, indicating potential deficits in air quality and opportunities for energy savings. This review highlights the need for holistic system design and consideration of parameter interactions to optimise energy efficiency and air quality.

Authors

Institutions

Publication Details

Journal
Indoor Air
Published
2025-01-01
DOI
https://doi.org/10.1155/ina/5224598
Citations
1
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
1.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ventilation Effectiveness: Overview of Terminology and Analysis of Influencing Parameters

Konstantinos Stergiaropoulos, Erik Bertram, Paul Hennies
1 citations
Indoor Air
Infection Control and Ventilation
1.52
article

Ventilation Effectiveness: Overview of Terminology and Analysis of Influencing Parameters

Konstantinos Stergiaropoulos, Erik Bertram, Paul Hennies
article en
1 citations

Abstract

Ventilation effectiveness evaluates the performance of ventilation systems by assessing air exchange and contaminant removal. Optimising ventilation effectiveness in mechanical ventilation systems reduces the required supply airflow rate while maintaining adequate indoor air quality. This review clarifies inconsistent definitions of ventilation effectiveness in standards and literature and provides a comprehensive overview of terms, definitions, and relevant parameters. The review also analyses the influence of variable and building‐fixed parameters on ventilation effectiveness using data from selected studies. Contaminant position and supply/exhaust position had the greatest impact on ventilation effectiveness, with maximum absolute changes of 2.1 and 0.94, respectively. Variable parameters, such as air change rate and temperature difference, showed moderate mean absolute changes of 0.28 and 0.15 but significant maximum deviations of 0.85 and 0.4. Building‐fixed parameters, including room size and aspect ratio, showed the least influence, with mean absolute changes below 0.1. These results highlight the importance of parameter interactions, such as short‐circuit flows caused by higher air velocities. In EN 16798‐1:2022, design values for required airflow are based on a ventilation effectiveness of 1. However, the analysis shows large variations around this value, indicating potential deficits in air quality and opportunities for energy savings. This review highlights the need for holistic system design and consideration of parameter interactions to optimise energy efficiency and air quality.

Indoor AirVol. 2025(1)
University of Stuttgart (DE), University of Applied Sciences and Arts Hildesheim/Holzminden/Göttingen (DE)
Openalex Percentile: Top 21%
Infection Control and Ventilation
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.