A novel method for brain aneurysms computed fluid dynamics analysis after flow diverter stent implantation based on micro-computed tomography reconstruction

Flow diverter stents are now increasingly utilised in the management of cerebral aneurysms. Computed flow simulation can be used to assess flow reduction and anticipate treatment outcome. To achieve this, the stent must be deployed virtually in the parent vessel carrying the aneurysm before running the simulation. This study proposes an alternative method to virtual deployment using micro-computer tomography after in vitro deployment of stents in silicone models to reconstruct accurately the struts over the aneurysm neck. Two experienced neuroradiologists deployed different stents (four 48-wire and one 64-wire pipeline embolization devices) in identical silicone models. Micro-CT acquisition was then carried out and allowed to reconstruct the stent meshes very accurately using different pre-processing steps. Virtual deployments were also performed for the two types of stents. Qualitatively, it was shown that the real deployments formed an inhomogeneous wire network compared to the regularity of the mesh of the virtually deployed stents. This difference had a moderate influence on hemodynamics. For virtual deployment, we observed an overestimation of the flow reduction of 5% and 16% for the 64- and 48-wire stents, respectively. While the flow patterns remained the same for the 48-wire stent, the 64-wire stent showed an inversion of the intra-aneurysmal vortex. This promising method could be used in the development of flow diverter devices or to conduct a comparative evaluation between different devices.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanics
Published
2025-03-20
DOI
https://doi.org/10.1016/j.jbiomech.2025.112634
Citations
1
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel method for brain aneurysms computed fluid dynamics analysis after flow diverter stent implantation based on micro-computed tomography reconstruction

Karl‐Olof Lövblad, Andrea Rosi, Philippe Reymond, Olivier Brina et al.
1 citations
Journal of Biomechanics
Intracranial Aneurysms: Treatment and Complications
1.39
article

A novel method for brain aneurysms computed fluid dynamics analysis after flow diverter stent implantation based on micro-computed tomography reconstruction

Karl‐Olof Lövblad, Andrea Rosi, Philippe Reymond, Olivier Brina, Gianmarco Bernava, Jérémy Hofmeister, Paolo Machi
article en
1 citations

Abstract

Flow diverter stents are now increasingly utilised in the management of cerebral aneurysms. Computed flow simulation can be used to assess flow reduction and anticipate treatment outcome. To achieve this, the stent must be deployed virtually in the parent vessel carrying the aneurysm before running the simulation. This study proposes an alternative method to virtual deployment using micro-computer tomography after in vitro deployment of stents in silicone models to reconstruct accurately the struts over the aneurysm neck. Two experienced neuroradiologists deployed different stents (four 48-wire and one 64-wire pipeline embolization devices) in identical silicone models. Micro-CT acquisition was then carried out and allowed to reconstruct the stent meshes very accurately using different pre-processing steps. Virtual deployments were also performed for the two types of stents. Qualitatively, it was shown that the real deployments formed an inhomogeneous wire network compared to the regularity of the mesh of the virtually deployed stents. This difference had a moderate influence on hemodynamics. For virtual deployment, we observed an overestimation of the flow reduction of 5% and 16% for the 64- and 48-wire stents, respectively. While the flow patterns remained the same for the 48-wire stent, the 64-wire stent showed an inversion of the intra-aneurysmal vortex. This promising method could be used in the development of flow diverter devices or to conduct a comparative evaluation between different devices.

Journal of BiomechanicsVol. 186
University Hospital of Geneva (CH), Geneva College (US)
Openalex Percentile: Top 22%
Intracranial Aneurysms: Treatment and Complications
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.