Determining the Accuracy of Patient-Specific Temporomandibular Joint Endoprostheses Using Navigational Surgical Templates

Abstract. Total joint replacement is indicated for congenital developmental anomalies, hereditary craniofacial syndromes, post-traumatic defects, deformities, ankylosis, severe degenerative osteoarthritis, condylar hyperplasia, mandibular tumors extending to the temporomandibular joint (TMJ), significant condylar resorption, osteonecrosis, and other conditions. Advancements in computer-aided design and manufacturing (CAD/CAM) technologies have led to the widespread use of patient-specific endoprostheses designed to accommodate each patient’s unique craniofacial anatomy. Navigation surgical guides have recently been increasingly recommended to place patient-specific constructs, osteotomies, and bone fragment repositioning. These guides enhance surgical precision by providing clear reference points and directional guidance. Objective. This study assessed the accuracy of TMJ patient-specific endoprosthesis placement achieved during surgery using navigation surgical guides compared to preoperative computer-aided planning. Additionally, factors influencing the magnitude of observed discrepancies were analyzed. Results and Conclusions. A comparative analysis of preoperative planning and postoperative outcomes in patients with TMJ disorders and trauma who underwent total joint replacement with patient-specific constructs fabricated using a digital protocol and CAD/CAM technology revealed discrepancies in the condylar component position. The median mean deviation was 1.02 mm (IQR 0.78–1.47), with a maximum deviation of 2.42 mm (IQR 2.03–4.26). In the glenoid fossa region, deviations were significantly lower (p < 0.05), with a median of 0.65 mm (IQR 0.47–1.16) and a maximum of 1.79 mm (IQR 1.46–2.02). These deviations were biomechanically acceptable and did not affect the aesthetic outcomes of endoprosthesis placement. In no case did the condylar head extend beyond the glenoid fossa due to its spatial configuration. Overall, the findings confirm the high precision of TMJ endoprosthesis placement using CAD/CAM technology. Keywords: temporomandibular joint, computer-aided design and manufacturing (CAD/CAM), surgical templates, ankylosis, endoprosthesis, patient-specific implant.

Authors

Publication Details

Journal
SUCHASNA STOMATOLOHIYA
Published
2025-01-01
DOI
https://doi.org/10.33295/1992-576x-2025-1-107
Citations
1
Primary Topic
Medical and Biological Sciences
Type
article
Field-Weighted Citation Impact
9.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determining the Accuracy of Patient-Specific Temporomandibular Joint Endoprostheses Using Navigational Surgical Templates

А. В. Копчак, Rostyslav Terletskyi, Yurii Chepurnyi
1 citations
SUCHASNA STOMATOLOHIYA
Medical and Biological Sciences
9.29
article

Determining the Accuracy of Patient-Specific Temporomandibular Joint Endoprostheses Using Navigational Surgical Templates

А. В. Копчак, Rostyslav Terletskyi, Yurii Chepurnyi
article en
1 citations

Abstract

Abstract. Total joint replacement is indicated for congenital developmental anomalies, hereditary craniofacial syndromes, post-traumatic defects, deformities, ankylosis, severe degenerative osteoarthritis, condylar hyperplasia, mandibular tumors extending to the temporomandibular joint (TMJ), significant condylar resorption, osteonecrosis, and other conditions. Advancements in computer-aided design and manufacturing (CAD/CAM) technologies have led to the widespread use of patient-specific endoprostheses designed to accommodate each patient’s unique craniofacial anatomy. Navigation surgical guides have recently been increasingly recommended to place patient-specific constructs, osteotomies, and bone fragment repositioning. These guides enhance surgical precision by providing clear reference points and directional guidance. Objective. This study assessed the accuracy of TMJ patient-specific endoprosthesis placement achieved during surgery using navigation surgical guides compared to preoperative computer-aided planning. Additionally, factors influencing the magnitude of observed discrepancies were analyzed. Results and Conclusions. A comparative analysis of preoperative planning and postoperative outcomes in patients with TMJ disorders and trauma who underwent total joint replacement with patient-specific constructs fabricated using a digital protocol and CAD/CAM technology revealed discrepancies in the condylar component position. The median mean deviation was 1.02 mm (IQR 0.78–1.47), with a maximum deviation of 2.42 mm (IQR 2.03–4.26). In the glenoid fossa region, deviations were significantly lower (p < 0.05), with a median of 0.65 mm (IQR 0.47–1.16) and a maximum of 1.79 mm (IQR 1.46–2.02). These deviations were biomechanically acceptable and did not affect the aesthetic outcomes of endoprosthesis placement. In no case did the condylar head extend beyond the glenoid fossa due to its spatial configuration. Overall, the findings confirm the high precision of TMJ endoprosthesis placement using CAD/CAM technology. Keywords: temporomandibular joint, computer-aided design and manufacturing (CAD/CAM), surgical templates, ankylosis, endoprosthesis, patient-specific implant.

SUCHASNA STOMATOLOHIYAVol. 124(1)
Openalex Percentile: Top 6%
Medical and Biological Sciences
9.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.