A dual-functional nanogold tablet as a plasmonic and nanozyme sensor for point-of-care applications

Point-of-care (POC) devices provide on-site disease diagnosis, particularly in resource-limited settings. Despite considerable progress in POC testing, the availability of commercial devices remains limited, primarily due to challenges in detection sensitivity and portability. Furthermore, advancements in existing POC devices are essential to better meet the needs of end-users. Herein, we present a colorimetric dual-functional tablet sensor using dextran-gold nanoparticles (dAuNPs) to detect and quantify uric acid and glucose levels in urine. Our tablet sensor combines the plasmonic and nanozyme properties of dAuNPs, resulting in highly sensitive detection of both biomarkers. Interestingly, we fabricated the nanogold tablet directly from the dAuNP solution without the addition of any external stabilizer or tablet-forming reagent, thus naming it a direct tablet. An enzyme-free approach was employed for uric acid detection, providing a wide detection range of 0.00187-7.8 mM and a low detection limit of 0.0037 mM, attributed to the hydrogen bonding between dextran and uric acid. On the other hand, the unique nanozyme properties of dAuNPs exhibited exclusive POx-mimetic activity for glucose detection (<i>K</i> <sub>m</sub> = 0.106 mM and <i>V</i> <sub>max</sub> = 369.72 mM min<sup>-1</sup>), with a lower detection limit of 0.625 mM. Our dual-functional tablet offers exceptional substrate selectivity for the colorimetric-chromogenic assay of both uric acid and glucose. This dual-functionality not only provides a highly sensitive, selective, and cost-effective detection strategy for resource-limited settings but also introduces a new avenue for designing customizable plasmonic-nanozyme nanogold tablet sensors as a powerful tool for rapid diagnosis.

Authors

Institutions

Publication Details

Journal
Nanoscale Advances
Published
2025-01-01
DOI
https://doi.org/10.1039/d5na00082c
Citations
2
Primary Topic
Advanced Nanomaterials in Catalysis
Type
article
Field-Weighted Citation Impact
1.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A dual-functional nanogold tablet as a plasmonic and nanozyme sensor for point-of-care applications

Zubi Sadiq, Sana Jahanshahi‐Anbuhi, Maryam Mansouri, Seyed Hamid Safiabadi Tali
2 citations
Nanoscale Advances
Advanced Nanomaterials in Catalysis
1.04
article

A dual-functional nanogold tablet as a plasmonic and nanozyme sensor for point-of-care applications

Zubi Sadiq, Sana Jahanshahi‐Anbuhi, Maryam Mansouri, Seyed Hamid Safiabadi Tali
article en
2 citations

Abstract

Point-of-care (POC) devices provide on-site disease diagnosis, particularly in resource-limited settings. Despite considerable progress in POC testing, the availability of commercial devices remains limited, primarily due to challenges in detection sensitivity and portability. Furthermore, advancements in existing POC devices are essential to better meet the needs of end-users. Herein, we present a colorimetric dual-functional tablet sensor using dextran-gold nanoparticles (dAuNPs) to detect and quantify uric acid and glucose levels in urine. Our tablet sensor combines the plasmonic and nanozyme properties of dAuNPs, resulting in highly sensitive detection of both biomarkers. Interestingly, we fabricated the nanogold tablet directly from the dAuNP solution without the addition of any external stabilizer or tablet-forming reagent, thus naming it a direct tablet. An enzyme-free approach was employed for uric acid detection, providing a wide detection range of 0.00187-7.8 mM and a low detection limit of 0.0037 mM, attributed to the hydrogen bonding between dextran and uric acid. On the other hand, the unique nanozyme properties of dAuNPs exhibited exclusive POx-mimetic activity for glucose detection (<i>K</i> <sub>m</sub> = 0.106 mM and <i>V</i> <sub>max</sub> = 369.72 mM min<sup>-1</sup>), with a lower detection limit of 0.625 mM. Our dual-functional tablet offers exceptional substrate selectivity for the colorimetric-chromogenic assay of both uric acid and glucose. This dual-functionality not only provides a highly sensitive, selective, and cost-effective detection strategy for resource-limited settings but also introduces a new avenue for designing customizable plasmonic-nanozyme nanogold tablet sensors as a powerful tool for rapid diagnosis.

Nanoscale AdvancesVol. 7(10)
Concordia University (CA)
McGill University, Concordia University, Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 27%
Advanced Nanomaterials in Catalysis
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A dual-functional nanogold tablet as a plasmonic and nanozyme sensor for point-of-care applications — Zubi Sadiq, Sana Jahanshahi‐Anbuhi, et al. · Nanoscale Advances (2025) | TGRS Research Map | TGRS