Two-axis compressed streak imaging (TACSI) fluorescence microscopy

Fluorescence microscopy is vital for biological discovery. Recent advances in fluorescent labels and proteins allow the correlation of multiple structures' timing, location, and interactions. Despite efficient fluorophores and sensitive cameras, sub-millisecond processes face read-noise and dynamic range constraints at high frame rates. High-speed cameras (upwards of one million FPS) suffer from high read-noise or low dynamic range, limiting their use in fluorescence microscopy. Compressed ultrafast photography (CUP) and streak-based systems achieve over 150 trillion FPS but have difficulty reconstructing stationary targets. We developed a compressed imaging method with a three-fold dynamic range improvement over conventional streak imaging for fluorescence microscopy with continuously illuminated, immobile objects with dynamic intensities. This technique achieves a 27 µs temporal resolution, demonstrated with fluorescent beads and CHO-K1 cells under pulsed electric fields loaded with voltage-sensitive dye.

Authors

Institutions

Publication Details

Published
2025-03-19
DOI
https://doi.org/10.1117/12.3038188
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-axis compressed streak imaging (TACSI) fluorescence microscopy

Vladislav V. Yakovlev, Joel N. Bixler, Zachary A. Steelman, Mark A. Keppler et al.
Advanced Fluorescence Microscopy Techniques
article

Two-axis compressed streak imaging (TACSI) fluorescence microscopy

Vladislav V. Yakovlev, Joel N. Bixler, Zachary A. Steelman, Mark A. Keppler, Sean P. O’Connor, Jinyang Liang
article en

Abstract

Fluorescence microscopy is vital for biological discovery. Recent advances in fluorescent labels and proteins allow the correlation of multiple structures' timing, location, and interactions. Despite efficient fluorophores and sensitive cameras, sub-millisecond processes face read-noise and dynamic range constraints at high frame rates. High-speed cameras (upwards of one million FPS) suffer from high read-noise or low dynamic range, limiting their use in fluorescence microscopy. Compressed ultrafast photography (CUP) and streak-based systems achieve over 150 trillion FPS but have difficulty reconstructing stationary targets. We developed a compressed imaging method with a three-fold dynamic range improvement over conventional streak imaging for fluorescence microscopy with continuously illuminated, immobile objects with dynamic intensities. This technique achieves a 27 µs temporal resolution, demonstrated with fluorescent beads and CHO-K1 cells under pulsed electric fields loaded with voltage-sensitive dye.

United States Air Force Research Laboratory (US), School of the Art Institute of Chicago (US), Texas A&M University (US)
Openalex Percentile: Top 95%
Advanced Fluorescence Microscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.