A Platform for the Glucose Biosensor Based on Dendritic Gold Nanostructures and Polyaniline-Gold Nanoparticles Nanocomposite

Diabetes mellitus is a pathological condition that requires continuous measurement of glucose concentration in human blood. In this study, two enzymatic mediator-free glucose biosensors based on premodified graphite rod (GR) electrodes were developed and compared. GR electrode modified with electrochemically synthesized dendritic gold nanostructures (DGNS), a cystamine (Cys) self-assembled monolayer (SAM), and glucose oxidase (GOx) (GR/DGNS/Cys/GOx) and GR electrode modified with DGNS, Cys SAM, enzymatically obtained polyaniline (PANI) nanocomposites with embedded 6 nm gold nanoparticles (AuNPs) and GOx (GR/DGNS/Cys/PANI-AuNPs-GOx/GOx) were investigated electrochemically. Biosensors based on GR/DGNS/Cys/GOx and GR/DGNS/Cys/PANI-AuNPs-GOx/GOx electrodes were characterized by a linear range (LR) of up to 1.0 mM of glucose, storage stability of over 71 days, sensitivity of 93.7 and 72.0 μA/(mM cm<sup>2</sup>), limit of detection (LOD) of 0.027 and 0.034 mM, reproducibility of 13.6 and 9.03%, and repeatability of 8.96 and 8.01%, respectively. The GR/DGNS/Cys/PANI-AuNPs-GOx/GOx electrode was proposed as more favorable for glucose concentration determination in serum due to its better stability and resistance to interfering electrochemically active species. The technological solutions presented in this paper are expected to enable the development of innovative mediator-free enzymatic glucose biosensors, offering advantages for clinical assays, particularly for controlling blood glucose concentration in individuals with diabetes.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-03-19
DOI
https://doi.org/10.3390/bios15030196
Citations
5
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
3.65

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Platform for the Glucose Biosensor Based on Dendritic Gold Nanostructures and Polyaniline-Gold Nanoparticles Nanocomposite

Anton Popov, Natalija German, Arūnas Ramanavičius, Almira Ramanavičienė
5 citations
Biosensors
Electrochemical sensors and biosensors
3.65
article

A Platform for the Glucose Biosensor Based on Dendritic Gold Nanostructures and Polyaniline-Gold Nanoparticles Nanocomposite

Anton Popov, Natalija German, Arūnas Ramanavičius, Almira Ramanavičienė
article en
5 citations

Abstract

Diabetes mellitus is a pathological condition that requires continuous measurement of glucose concentration in human blood. In this study, two enzymatic mediator-free glucose biosensors based on premodified graphite rod (GR) electrodes were developed and compared. GR electrode modified with electrochemically synthesized dendritic gold nanostructures (DGNS), a cystamine (Cys) self-assembled monolayer (SAM), and glucose oxidase (GOx) (GR/DGNS/Cys/GOx) and GR electrode modified with DGNS, Cys SAM, enzymatically obtained polyaniline (PANI) nanocomposites with embedded 6 nm gold nanoparticles (AuNPs) and GOx (GR/DGNS/Cys/PANI-AuNPs-GOx/GOx) were investigated electrochemically. Biosensors based on GR/DGNS/Cys/GOx and GR/DGNS/Cys/PANI-AuNPs-GOx/GOx electrodes were characterized by a linear range (LR) of up to 1.0 mM of glucose, storage stability of over 71 days, sensitivity of 93.7 and 72.0 μA/(mM cm<sup>2</sup>), limit of detection (LOD) of 0.027 and 0.034 mM, reproducibility of 13.6 and 9.03%, and repeatability of 8.96 and 8.01%, respectively. The GR/DGNS/Cys/PANI-AuNPs-GOx/GOx electrode was proposed as more favorable for glucose concentration determination in serum due to its better stability and resistance to interfering electrochemically active species. The technological solutions presented in this paper are expected to enable the development of innovative mediator-free enzymatic glucose biosensors, offering advantages for clinical assays, particularly for controlling blood glucose concentration in individuals with diabetes.

BiosensorsVol. 15(3)
Vilnius University (LT), State Research Institute Centre for Innovative Medicine (LT)
Lietuvos Mokslo Taryba
Openalex Percentile: Top 7%
Electrochemical sensors and biosensors
3.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.