Self-calibration method for spiral CT geometric parameters based on data redundancy conditions

The geometric parameters of the CT system significantly influence the quality of reconstructed images and the accuracy of dimensional measurements. To achieve precise calibration of these parameters, this study develops a self-calibration method for spiral CT geometry based on data redundancy conditions. Theoretical analysis is conducted to identify the geometric relationships that satisfy data redundancy under spiral scanning trajectories. Using simulation data, we investigate the effects of three key geometric parameters-the source-to-sample distance, the horizontal offset of the detector, and the rotation angle in detector plane-on data redundancy. Additionally, we examine how varying noise levels impact the accuracy of geometric parameter estimation. Finally, the proposed method is validated through spiral CT scanning experiments with real samples. Results show that the calculation accuracy for the detector's horizontal offset is better than 1 pixel, the rotation angle in detector plane accuracy exceeds 0.1°, and the source-to-sample distance accuracy surpasses 0.42%. These findings confirm the effectiveness of the proposed method in practical applications.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-03-20
DOI
https://doi.org/10.1364/oe.559208
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-calibration method for spiral CT geometric parameters based on data redundancy conditions

Bozhong Tan, Jinming Cheng, Qingguo Yang
Optics Express
Advanced X-ray and CT Imaging
article

Self-calibration method for spiral CT geometric parameters based on data redundancy conditions

Bozhong Tan, Jinming Cheng, Qingguo Yang
article en

Abstract

The geometric parameters of the CT system significantly influence the quality of reconstructed images and the accuracy of dimensional measurements. To achieve precise calibration of these parameters, this study develops a self-calibration method for spiral CT geometry based on data redundancy conditions. Theoretical analysis is conducted to identify the geometric relationships that satisfy data redundancy under spiral scanning trajectories. Using simulation data, we investigate the effects of three key geometric parameters-the source-to-sample distance, the horizontal offset of the detector, and the rotation angle in detector plane-on data redundancy. Additionally, we examine how varying noise levels impact the accuracy of geometric parameter estimation. Finally, the proposed method is validated through spiral CT scanning experiments with real samples. Results show that the calculation accuracy for the detector's horizontal offset is better than 1 pixel, the rotation angle in detector plane accuracy exceeds 0.1°, and the source-to-sample distance accuracy surpasses 0.42%. These findings confirm the effectiveness of the proposed method in practical applications.

Optics ExpressVol. 33(7)
China Academy of Engineering Physics (CN)
Openalex Percentile: Top 95%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.