The Influence of Soil Two-Layer Structures on Substation Safety in Lightning Strike Conditions

Abstract Substation is one part of the electric power transmission system. In its distribution, it is inseparable from disturbances caused by lightning strikes. The disturbance occurs directly or indirectly so that a safety system is needed to prevent damage to equipment and personal safety. The safety system in question is the grounding system. A good grounding system will produce low soil resistivity. To obtain accurate soil resistivity values, soil type and grid configuration are very influential. This study discusses the rod grounding system with a square shape, touch voltage, step voltage on a two-layer soil structure. The grid configuration is equipped with varying conductor distances and conductor lengths. This study aims to determine the effect of the two-layer soil structure on the safety of the substation caused by lightning strike disturbances. The waveform simulation varies with a magnitude of 25 kA, 50 kA, 75 kA, and 100 kA.

Authors

Institutions

Publication Details

Journal
IOP Conference Series Earth and Environmental Science
Published
2025-03-01
DOI
https://doi.org/10.1088/1755-1315/1463/1/012005
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Influence of Soil Two-Layer Structures on Substation Safety in Lightning Strike Conditions

Sri Melvani Hardi, Muhd Hafizi Idris, DP Wardani, EP Sinulingga
IOP Conference Series Earth and Environmental Science
Lightning and Electromagnetic Phenomena
article

The Influence of Soil Two-Layer Structures on Substation Safety in Lightning Strike Conditions

Sri Melvani Hardi, Muhd Hafizi Idris, DP Wardani, EP Sinulingga
article en

Abstract

Abstract Substation is one part of the electric power transmission system. In its distribution, it is inseparable from disturbances caused by lightning strikes. The disturbance occurs directly or indirectly so that a safety system is needed to prevent damage to equipment and personal safety. The safety system in question is the grounding system. A good grounding system will produce low soil resistivity. To obtain accurate soil resistivity values, soil type and grid configuration are very influential. This study discusses the rod grounding system with a square shape, touch voltage, step voltage on a two-layer soil structure. The grid configuration is equipped with varying conductor distances and conductor lengths. This study aims to determine the effect of the two-layer soil structure on the safety of the substation caused by lightning strike disturbances. The waveform simulation varies with a magnitude of 25 kA, 50 kA, 75 kA, and 100 kA.

IOP Conference Series Earth and Environmental ScienceVol. 1463(1)
Universitas Sumatera Utara (ID), Universiti Malaysia Perlis (MY)
Openalex Percentile: Top 90%
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.