Dacron® Graft Kinking Following Ascending Aorta Replacement Is Not Only a Cosmetic Issue

A 58-year-old man, who has undergone ascending aorta replacement, started to complain of pain in the lower limbs, shortness of breath, and progressive fatigue a few months after surgery. Transthoracic and transesophageal Doppler echocardiographies revealed a diseased bicuspid aortic valve and a subocclusive mass in the ascending aorta. Thoracic computed tomography angiography confirmed the presence of a subocclusive mass, pseudoaneurysm formation, and a distorted shape of the Dacron® graft. The patient underwent urgent surgery to remove the mass, which appeared to be a thrombus, and aortic valve and ascending aorta replacement. Kinking of vascular graft has been reported including surgical techniques to correct the excessive length to avoid gradients and guarantee laminar flow. When kinking is severe, high gradients and hemolysis can be detected. However, thrombus formation in the ascending aorta segment is less likely, due to the high blood velocity flow. Therefore, several concurrent causes should be considered. In this case, the most probable explanation for thrombus formation was kinking of a too long Dacron® graft, combined with extrinsic compression effect of the graft by the pseudoaneurysm at the anastomosis site and anomalous flow directed from the diseased bicuspid aortic valve. Various grades of Dacron® graft kinking might occur following ascending aorta replacement and undiagnosed at follow-up especially if resulting in mild symptoms, thus, careful visual and echocardiography evaluation should be done at the end of surgery. Finally, distorted Dacron® graft might trigger thrombus formation when inflammation and coagulation processes are set off during bacteria or viral infection.

Authors

Institutions

Publication Details

Journal
Brazilian Journal of Cardiovascular Surgery
Published
2025-01-01
DOI
https://doi.org/10.21470/1678-9741-2022-0468
Citations
1
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
1.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dacron® Graft Kinking Following Ascending Aorta Replacement Is Not Only a Cosmetic Issue

Ermal Likaj, Alfred Ibrahimi, Jacob Zeitani, Saimir Kuçi
1 citations
Brazilian Journal of Cardiovascular Surgery
Aortic Disease and Treatment Approaches
1.52
article

Dacron® Graft Kinking Following Ascending Aorta Replacement Is Not Only a Cosmetic Issue

Ermal Likaj, Alfred Ibrahimi, Jacob Zeitani, Saimir Kuçi
article en
1 citations

Abstract

A 58-year-old man, who has undergone ascending aorta replacement, started to complain of pain in the lower limbs, shortness of breath, and progressive fatigue a few months after surgery. Transthoracic and transesophageal Doppler echocardiographies revealed a diseased bicuspid aortic valve and a subocclusive mass in the ascending aorta. Thoracic computed tomography angiography confirmed the presence of a subocclusive mass, pseudoaneurysm formation, and a distorted shape of the Dacron® graft. The patient underwent urgent surgery to remove the mass, which appeared to be a thrombus, and aortic valve and ascending aorta replacement. Kinking of vascular graft has been reported including surgical techniques to correct the excessive length to avoid gradients and guarantee laminar flow. When kinking is severe, high gradients and hemolysis can be detected. However, thrombus formation in the ascending aorta segment is less likely, due to the high blood velocity flow. Therefore, several concurrent causes should be considered. In this case, the most probable explanation for thrombus formation was kinking of a too long Dacron® graft, combined with extrinsic compression effect of the graft by the pseudoaneurysm at the anastomosis site and anomalous flow directed from the diseased bicuspid aortic valve. Various grades of Dacron® graft kinking might occur following ascending aorta replacement and undiagnosed at follow-up especially if resulting in mild symptoms, thus, careful visual and echocardiography evaluation should be done at the end of surgery. Finally, distorted Dacron® graft might trigger thrombus formation when inflammation and coagulation processes are set off during bacteria or viral infection.

Brazilian Journal of Cardiovascular SurgeryVol. 40(2)
University of Ferrara (IT), Mother Teresa Hospital (AL)
Good health and well-being
Openalex Percentile: Top 21%
Aortic Disease and Treatment Approaches
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dacron® Graft Kinking Following Ascending Aorta Replacement Is Not Only a Cosmetic Issue — Ermal Likaj, Alfred Ibrahimi, et al. · Brazilian Journal of Cardiovascular Surgery (2025) | TGRS Research Map | TGRS