The Combined Utilization of Epithelial Thickness and Tomographic Parameters in Keratoconus Detection

<b>Purpose:</b> To evaluate the performance of the anterior segment optical coherence tomography (AS-OCT) and Scheimpflug-Placido tomographic (SPT) indices in differentiating suspect keratoconus (SKC) from normal (N). <b>Methods:</b> In this cross-sectional study, one eye of each patient was scanned on AS-OCT and SPT. Following, 5 regression analysis models were developed: Model 1: combined AS-OCT corneal thickness (CT); Model 2: combined AS-OCT epithelial thickness (ET); Model 3: Models 1 + 2; Model 4: SPT indices (symmetry index front [SIf], symmetry index back [SIb], keratoconus vertex back [KVb], and minimum CT [ThkMin]); Model 5: Models 3 + 4. The areas under the curve (AUC) of receiver operator characteristic (ROC) curves were compared across groups to estimate their performance accuracy. <b>Results:</b> Two hundred and five N eyes, 56 SKC eyes, and 89 keratoconus (KC) eyes were scanned with AS-OCT and SPT. For Models 1 and 2, no individual metric yielded an AUC > 0.84. For Model 3, the AUC was 0.96 (R2 Nagelkerke: 0.69) with 90.28% cases correctly identified as SKC. For Model 4, the AUC was 0.99 (R2 Nagelkerke: 0.87), with 95.58% of cases correctly classified as SKC. For Model 5, the diagnostic accuracy did not improve compared to Model 4. <b>Conclusion:</b> Both combined AS-OCT indices and combined SPT indices provided excellent diagnostic power to differentiate SKC from N eyes. The combined SPT model showed a superior value compared to the AS-OCT model. Furthermore, combined AS-OCT and SPT data did not perform better than the combined SPT data alone.

Authors

Institutions

Publication Details

Journal
Journal of Ophthalmology
Published
2025-01-01
DOI
https://doi.org/10.1155/joph/6647993
Citations
1
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Combined Utilization of Epithelial Thickness and Tomographic Parameters in Keratoconus Detection

Taym Darwish, Marwan Ghabra, Abdelrahman Salman, Mayank Ambarish Nanavaty et al.
1 citations
Journal of Ophthalmology
Corneal surgery and disorders
1.36
article

The Combined Utilization of Epithelial Thickness and Tomographic Parameters in Keratoconus Detection

Taym Darwish, Marwan Ghabra, Abdelrahman Salman, Mayank Ambarish Nanavaty, Buraa Kubaisi, Obeda Kailani, Rana Omran, Omar Badla, Rafea Shaaban, Zein Baradi, Mohamed Khallouf
article en
1 citations

Abstract

<b>Purpose:</b> To evaluate the performance of the anterior segment optical coherence tomography (AS-OCT) and Scheimpflug-Placido tomographic (SPT) indices in differentiating suspect keratoconus (SKC) from normal (N). <b>Methods:</b> In this cross-sectional study, one eye of each patient was scanned on AS-OCT and SPT. Following, 5 regression analysis models were developed: Model 1: combined AS-OCT corneal thickness (CT); Model 2: combined AS-OCT epithelial thickness (ET); Model 3: Models 1 + 2; Model 4: SPT indices (symmetry index front [SIf], symmetry index back [SIb], keratoconus vertex back [KVb], and minimum CT [ThkMin]); Model 5: Models 3 + 4. The areas under the curve (AUC) of receiver operator characteristic (ROC) curves were compared across groups to estimate their performance accuracy. <b>Results:</b> Two hundred and five N eyes, 56 SKC eyes, and 89 keratoconus (KC) eyes were scanned with AS-OCT and SPT. For Models 1 and 2, no individual metric yielded an AUC > 0.84. For Model 3, the AUC was 0.96 (R2 Nagelkerke: 0.69) with 90.28% cases correctly identified as SKC. For Model 4, the AUC was 0.99 (R2 Nagelkerke: 0.87), with 95.58% of cases correctly classified as SKC. For Model 5, the diagnostic accuracy did not improve compared to Model 4. <b>Conclusion:</b> Both combined AS-OCT indices and combined SPT indices provided excellent diagnostic power to differentiate SKC from N eyes. The combined SPT model showed a superior value compared to the AS-OCT model. Furthermore, combined AS-OCT and SPT data did not perform better than the combined SPT data alone.

Journal of OphthalmologyVol. 2025(1)
Latakia University (SY), Damascus Hospital (SY), Al Andalus University (SY), Whipps Cross University Hospital (GB), King's College Hospital NHS Foundation Trust (GB), Ministry of Culture (SY), Miami Transplant Institute (US), University Hospitals Sussex NHS Foundation Trust (GB), Arab Board Of Health Specializations (SY), University of Tartu (EE)
Openalex Percentile: Top 22%
Corneal surgery and disorders
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.