Study on the Influence Law and Prediction of Anode Ground Bed Design Parameters on Cathodic Protection Potential in Buried Pipeline Areas

ABSTRACT Corrosion of underground metal structures in oil and gas stations requires effective cathodic protection, with anode ground bed design being crucial. This study determined average soil resistivity and cathodic polarization curves based on field data. A numerical model of the buried pipeline network was established using COMSOL Multiphysics, and the distribution of protection potential was analyzed under different anode ground bed design parameters. Using the national CSE standard for protection potential, a decision tree model was also created. Results show a negative correlation between protection potential and the number of auxiliary anodes, anode ground bed groups, and anode size. The most negative protection potential occurs at burial depths of approximately 2.5–3.5 m. The number of anode ground bed groups and the size of auxiliary anodes have a greater impact on protection, while burial depth does not require specific setup conditions.

Authors

Institutions

Publication Details

Journal
Materials and Corrosion
Published
2025-03-19
DOI
https://doi.org/10.1002/maco.202414754
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Influence Law and Prediction of Anode Ground Bed Design Parameters on Cathodic Protection Potential in Buried Pipeline Areas

Rufei Ma, Kai Zhang, Peng Zhang, Sen Zhang et al.
Materials and Corrosion
Concrete Corrosion and Durability
article

Study on the Influence Law and Prediction of Anode Ground Bed Design Parameters on Cathodic Protection Potential in Buried Pipeline Areas

Rufei Ma, Kai Zhang, Peng Zhang, Sen Zhang, Liqiong Chen, Ting He
article en

Abstract

ABSTRACT Corrosion of underground metal structures in oil and gas stations requires effective cathodic protection, with anode ground bed design being crucial. This study determined average soil resistivity and cathodic polarization curves based on field data. A numerical model of the buried pipeline network was established using COMSOL Multiphysics, and the distribution of protection potential was analyzed under different anode ground bed design parameters. Using the national CSE standard for protection potential, a decision tree model was also created. Results show a negative correlation between protection potential and the number of auxiliary anodes, anode ground bed groups, and anode size. The most negative protection potential occurs at burial depths of approximately 2.5–3.5 m. The number of anode ground bed groups and the size of auxiliary anodes have a greater impact on protection, while burial depth does not require specific setup conditions.

Materials and CorrosionVol. 76(8)
Southwest Petroleum University (CN)
Life in Land
Openalex Percentile: Top 94%
Concrete Corrosion and Durability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study on the Influence Law and Prediction of Anode Ground Bed Design Parameters on Cathodic Protection Potential in Buried Pipeline Areas — Rufei Ma, Kai Zhang, et al. · Materials and Corrosion (2025) | TGRS Research Map | TGRS