Clinical Application Analysis of Orthopedic Robot-Assisted Treatment for Lumbar Spondylolisthesis

Objective: To explore the clinical efficacy of orthopedic robot-assisted treatment for lumbar spondylolisthesis, focusing on the analysis of key indicators such as intraoperative blood loss, postoperative complications, and accuracy of nail placement, providing a reference basis for the widespread application of this technology. Methods: Retrospective analysis of clinical data of 25 patients with lumbar spondylolisthesis who underwent surgery with Tianji orthopedic robot assistance at Baise People’s Hospital from June 2021 to December 2024, with an age of (59.72 ± 8.44) years, range: (45 - 80) years. Before surgery, all 25 patients had single-segment spondylolisthesis, 7 males, 18 females, L4/5 segment in 17 cases, L5/S1 in 7 cases, L3/4 in 1 case. Before surgery, 17 cases were grade I slippage, and 8 cases were grade II slippage. Through intraoperative and postoperative observation and follow-up, and statistical analysis of data such as intraoperative blood loss, postoperative complications, and nail placement accuracy to analyze the value of orthopedic robots in clinical applications. Results: The intraoperative blood loss under robot-assisted surgery was (209.60 ± 127.09) ml, the duration of surgery was (165.92 ± 16.08) min, the number of fluoroscopies during surgery was (2.24 ± 1.249) times, the postoperative hospital stay was (7.56 ± 1.83) days, the follow-up time after surgery was (9.52 ± 2.69) months, and the accuracy of nail placement was 96%. The visual analog scale (VAS) pain scores were 5.20 ± 0.76 at one week after surgery and 2.20 ± 0.87 at the last follow-up, both lower than the preoperative score of 7.72 ± 1.14, with statistical significance (p 2 = 307.6, p Conclusion: Orthopedic robot-assisted treatment for lumbar spondylolisthesis has significant advantages and important reference value in clinical applications.

Authors

Publication Details

Journal
E-Health Telecommunication Systems and Networks
Published
2025-01-01
DOI
https://doi.org/10.4236/etsn.2025.141002
Primary Topic
Spine and Intervertebral Disc Pathology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical Application Analysis of Orthopedic Robot-Assisted Treatment for Lumbar Spondylolisthesis

Chengkua Huang, Xianhai Zeng, Guosheng Su, Nong Sheng et al.
E-Health Telecommunication Systems and Networks
Spine and Intervertebral Disc Pathology
article

Clinical Application Analysis of Orthopedic Robot-Assisted Treatment for Lumbar Spondylolisthesis

Chengkua Huang, Xianhai Zeng, Guosheng Su, Nong Sheng, Junlei Tan, Yuanjian Huang, Mei Zhang, Qianhou Zhou, W.-C. Yang
article en

Abstract

Objective: To explore the clinical efficacy of orthopedic robot-assisted treatment for lumbar spondylolisthesis, focusing on the analysis of key indicators such as intraoperative blood loss, postoperative complications, and accuracy of nail placement, providing a reference basis for the widespread application of this technology. Methods: Retrospective analysis of clinical data of 25 patients with lumbar spondylolisthesis who underwent surgery with Tianji orthopedic robot assistance at Baise People’s Hospital from June 2021 to December 2024, with an age of (59.72 ± 8.44) years, range: (45 - 80) years. Before surgery, all 25 patients had single-segment spondylolisthesis, 7 males, 18 females, L4/5 segment in 17 cases, L5/S1 in 7 cases, L3/4 in 1 case. Before surgery, 17 cases were grade I slippage, and 8 cases were grade II slippage. Through intraoperative and postoperative observation and follow-up, and statistical analysis of data such as intraoperative blood loss, postoperative complications, and nail placement accuracy to analyze the value of orthopedic robots in clinical applications. Results: The intraoperative blood loss under robot-assisted surgery was (209.60 ± 127.09) ml, the duration of surgery was (165.92 ± 16.08) min, the number of fluoroscopies during surgery was (2.24 ± 1.249) times, the postoperative hospital stay was (7.56 ± 1.83) days, the follow-up time after surgery was (9.52 ± 2.69) months, and the accuracy of nail placement was 96%. The visual analog scale (VAS) pain scores were 5.20 ± 0.76 at one week after surgery and 2.20 ± 0.87 at the last follow-up, both lower than the preoperative score of 7.72 ± 1.14, with statistical significance (p 2 = 307.6, p Conclusion: Orthopedic robot-assisted treatment for lumbar spondylolisthesis has significant advantages and important reference value in clinical applications.

E-Health Telecommunication Systems and NetworksVol. 14(01)
Openalex Percentile: Top 93%
Spine and Intervertebral Disc Pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.