Initial Urological Surgery Using a New Domestic Single-Port Surgical Robotic System

<b><i>Purpose:</i></b> To determine the feasibility and safety of a new domestic single-port surgical robot in urologic partial nephrectomy and radical prostatectomy, as measured by the primary metric outcome (surgical success rate). In addition, this study measured important perioperative surgical outcomes, such as operative time, blood loss, postoperative length of stay, docking time, and thermal ischemia time, and reported pathologic data using the surgical robot. <b><i>Materials and Methods:</i></b> This prospective, single-center, single-group clinical study was conducted between August 2023 and October 2023. One surgeon used a new domestic single-port surgical robot (EDGE SP1000) to perform six urologic procedures, including three partial nephrectomies and three extraperitoneal radical prostatectomies. Perioperative data were prospectively recorded, early oncologic outcomes were assessed based on the surgical margin status, and equipment ergonomic comfort was assessed using the National Aeronautics and Space Administration Task Load Index (NASA-TLX). <b><i>Results:</i></b> All six procedures were effectively completed without conversion to open surgery, laparoscopy, or use of multiport robots. The average total operation time was 207.92 ± 32.42 minutes, estimated blood loss was 100 mL (10-900 mL), and postoperative hospital stay was 8.67 ± 1.33 days. The average docking time was 16.25 ± 5.68 minutes, and warm ischemia time was 17.00 ± 2.65 minutes. None of the patients required perioperative blood transfusion. All pathologic examination margins were negative. No serious perioperative complications occurred (Clavien-Dindo grade 3). The surgeon reported that the device was comfortable to use, with a NASA-TLX score of 35.67 ± 4.23. <b><i>Conclusions:</i></b> It is safe and feasible to perform urologic procedure using the EDGE single-port endoscopic surgical robot (EDGE SP1000) control system.

Authors

Institutions

Publication Details

Journal
Journal of Endourology
Published
2025-03-19
DOI
https://doi.org/10.1089/end.2024.0822
Citations
1
Primary Topic
Minimally Invasive Surgical Techniques
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Initial Urological Surgery Using a New Domestic Single-Port Surgical Robotic System

Xinghuan Wang, Kun Yang, Wen Zhong, Honghua Zhou et al.
1 citations
Journal of Endourology
Minimally Invasive Surgical Techniques
2.01
article

Initial Urological Surgery Using a New Domestic Single-Port Surgical Robotic System

Xinghuan Wang, Kun Yang, Wen Zhong, Honghua Zhou, Zhang Lin, Hang Zheng
article en
1 citations

Abstract

<b><i>Purpose:</i></b> To determine the feasibility and safety of a new domestic single-port surgical robot in urologic partial nephrectomy and radical prostatectomy, as measured by the primary metric outcome (surgical success rate). In addition, this study measured important perioperative surgical outcomes, such as operative time, blood loss, postoperative length of stay, docking time, and thermal ischemia time, and reported pathologic data using the surgical robot. <b><i>Materials and Methods:</i></b> This prospective, single-center, single-group clinical study was conducted between August 2023 and October 2023. One surgeon used a new domestic single-port surgical robot (EDGE SP1000) to perform six urologic procedures, including three partial nephrectomies and three extraperitoneal radical prostatectomies. Perioperative data were prospectively recorded, early oncologic outcomes were assessed based on the surgical margin status, and equipment ergonomic comfort was assessed using the National Aeronautics and Space Administration Task Load Index (NASA-TLX). <b><i>Results:</i></b> All six procedures were effectively completed without conversion to open surgery, laparoscopy, or use of multiport robots. The average total operation time was 207.92 ± 32.42 minutes, estimated blood loss was 100 mL (10-900 mL), and postoperative hospital stay was 8.67 ± 1.33 days. The average docking time was 16.25 ± 5.68 minutes, and warm ischemia time was 17.00 ± 2.65 minutes. None of the patients required perioperative blood transfusion. All pathologic examination margins were negative. No serious perioperative complications occurred (Clavien-Dindo grade 3). The surgeon reported that the device was comfortable to use, with a NASA-TLX score of 35.67 ± 4.23. <b><i>Conclusions:</i></b> It is safe and feasible to perform urologic procedure using the EDGE single-port endoscopic surgical robot (EDGE SP1000) control system.

Journal of EndourologyVol. 39(4)
Wuhan University (CN), Wuhan Wudong Hospital (CN), Zhongnan Hospital of Wuhan University (CN)
Openalex Percentile: Top 18%
Minimally Invasive Surgical Techniques
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.