Background: More often than any other type of contra-ception, intrauterine contraceptive devices (IUCDs) are used in Egypt. In most cases, a non-guided procedure is used to insert IUCDs in office settings. Blind insertion possibly causes various complications including perfora-tion. It is recommended to conduct TVUS prior to inser-tion in order to determine the uterus's size and orienta-tion, as well as to rule out the possibility of pregnancy or pathology. Moreover use of TVUS during regular follow up may improve outcomes and help reduce IUCD related complications. Aim of the work: Compare ultrasound-guided and non-ultrasound-guided IUCD insertion techniques for proper placement, problems, time, and patient satisfaction during insertion and follow-up.Patients and methods: The study recruited 200 women using copper TCu-380A that were randomly divided into two groups (Each of 100 females), subgroup U (where ultrasound guided technique before insertion, during in-sertion and follow up and subgroup B (with non-ultra-sound guided technique for IUCD insertion). The prima-ry outcome was measuring the proper device placement post-insertion and after the next menstruation. Secondary outcomes included measuring the incidence of complica-tions including perforation, expulsion, cervical problems, bradycardia, syncope, measuring patient satisfaction, as-sessment of difficult IUCD insertion and pain scores. Results: The overall incidence of complications was sta-tistically significantly higher in the non-ultrasound guid-ed technique group as compared to the ultrasound group. The duration for insertion was statistically significantly longer in the non-ultrasound guided technique group as compared to the ultrasound group. The Pain score during insertion was statistically significantly higher in the non-ultrasound guided technique group as compared to the ultrasound group. The degree of satisfaction was sta-tistically significantly higher in the ultrasound technique group. Conclusions: Several positive outcomes were linked to the use of TVUS during the insertion of IUCD, including a shorter inser-tion duration, lower pain levels, a higher de-gree of satisfaction, and a smaller frequency of problems. Also, TVUS scan during regu-lar follow up substantially help reduce IUCD related complications and improve continui-ty of the method.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Fertility of Sterility
Published
2025-03-01
DOI
https://doi.org/10.21608/egyfs.2025.417775
Primary Topic
Reproductive Health and Contraception
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Role of Ultrasonography in Intrauterine Contraceptive Device Utilization in Mansoura University Hospital

Mohamed M. Elmorsy, Hanan Nabil Abdel Hafez, Hind Saad Ibrahem Ali El Shoubaky, Abdel Mageed Fathy Mashsly
The Egyptian Journal of Fertility of Sterility
Reproductive Health and Contraception
article

Role of Ultrasonography in Intrauterine Contraceptive Device Utilization in Mansoura University Hospital

Mohamed M. Elmorsy, Hanan Nabil Abdel Hafez, Hind Saad Ibrahem Ali El Shoubaky, Abdel Mageed Fathy Mashsly
article en

Abstract

Background: More often than any other type of contra-ception, intrauterine contraceptive devices (IUCDs) are used in Egypt. In most cases, a non-guided procedure is used to insert IUCDs in office settings. Blind insertion possibly causes various complications including perfora-tion. It is recommended to conduct TVUS prior to inser-tion in order to determine the uterus's size and orienta-tion, as well as to rule out the possibility of pregnancy or pathology. Moreover use of TVUS during regular follow up may improve outcomes and help reduce IUCD related complications. Aim of the work: Compare ultrasound-guided and non-ultrasound-guided IUCD insertion techniques for proper placement, problems, time, and patient satisfaction during insertion and follow-up.Patients and methods: The study recruited 200 women using copper TCu-380A that were randomly divided into two groups (Each of 100 females), subgroup U (where ultrasound guided technique before insertion, during in-sertion and follow up and subgroup B (with non-ultra-sound guided technique for IUCD insertion). The prima-ry outcome was measuring the proper device placement post-insertion and after the next menstruation. Secondary outcomes included measuring the incidence of complica-tions including perforation, expulsion, cervical problems, bradycardia, syncope, measuring patient satisfaction, as-sessment of difficult IUCD insertion and pain scores. Results: The overall incidence of complications was sta-tistically significantly higher in the non-ultrasound guid-ed technique group as compared to the ultrasound group. The duration for insertion was statistically significantly longer in the non-ultrasound guided technique group as compared to the ultrasound group. The Pain score during insertion was statistically significantly higher in the non-ultrasound guided technique group as compared to the ultrasound group. The degree of satisfaction was sta-tistically significantly higher in the ultrasound technique group. Conclusions: Several positive outcomes were linked to the use of TVUS during the insertion of IUCD, including a shorter inser-tion duration, lower pain levels, a higher de-gree of satisfaction, and a smaller frequency of problems. Also, TVUS scan during regu-lar follow up substantially help reduce IUCD related complications and improve continui-ty of the method.

The Egyptian Journal of Fertility of SterilityVol. 29(2)
Mansoura University (EG)
Good health and well-being
Openalex Percentile: Top 93%
Reproductive Health and Contraception
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.