Design and commissioning of a THz time-domain spectro-goniometer in a cryogenic comet simulation chamber

We present our newly developed laboratory setup, called COCoNuT (Characteristic Observation of Cometary Nuclei using THz-spectroscopy), consisting of a THz spectro-goniometer in a vacuum chamber along with a cryo-cooler intended for cooling down samples rich in ices expected in cometary environments. This setup allows the use of THz time domain spectroscopy on analogs including refractory materials in the spectral range from 0.1 to 5.5 THz with a spectral resolution of up to 0.005 THz. Since the optical setup is mounted on a precision controlled x/y-stage, imaging or spatial averaging can be performed. In this work, we present the design decisions and selection of components. Furthermore, the commissioning of the setup is described and the capabilities are shown. The system can reach pressures of 10-7 mbar and temperatures of 50 K. For 2D scanning, a spatial resolution of 0.3 line-pair per mm is obtained.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-03-01
DOI
https://doi.org/10.1063/5.0252742
Citations
3
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
2.27

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and commissioning of a THz time-domain spectro-goniometer in a cryogenic comet simulation chamber

Mathias Brändli, A. Pommerol, Rafael Ottersberg, Axel Murk et al.
3 citations
Review of Scientific Instruments
Spectroscopy and Laser Applications
2.27
article

Design and commissioning of a THz time-domain spectro-goniometer in a cryogenic comet simulation chamber

Mathias Brändli, A. Pommerol, Rafael Ottersberg, Axel Murk, N. Thomas, Linus Leo Stöckli, D. Piazza
article en
3 citations

Abstract

We present our newly developed laboratory setup, called COCoNuT (Characteristic Observation of Cometary Nuclei using THz-spectroscopy), consisting of a THz spectro-goniometer in a vacuum chamber along with a cryo-cooler intended for cooling down samples rich in ices expected in cometary environments. This setup allows the use of THz time domain spectroscopy on analogs including refractory materials in the spectral range from 0.1 to 5.5 THz with a spectral resolution of up to 0.005 THz. Since the optical setup is mounted on a precision controlled x/y-stage, imaging or spatial averaging can be performed. In this work, we present the design decisions and selection of components. Furthermore, the commissioning of the setup is described and the capabilities are shown. The system can reach pressures of 10-7 mbar and temperatures of 50 K. For 2D scanning, a spatial resolution of 0.3 line-pair per mm is obtained.

Review of Scientific InstrumentsVol. 96(3)
University of Bern (CH)
European Space Agency, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, Staatssekretariat für Bildung, Forschung und Innovation
Openalex Percentile: Top 13%
Spectroscopy and Laser Applications
2.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and commissioning of a THz time-domain spectro-goniometer in a cryogenic comet simulation chamber — Mathias Brändli, A. Pommerol, et al. · Review of Scientific Instruments (2025) | TGRS Research Map | TGRS