Gold Nanoparticle-Enhanced Graphene Immunosensor for Rapid Detection of Gardnerella vaginalis in Clinical Diagnostics

The global market increasingly demands alternative rapid diagnostic tools, such as disposable biosensors, to meet the growing need for point-of-care clinical testing of infectious diseases. Bacterial vaginosis (BV), a common infection caused by Gardnerella vaginalis, requires efficient and accurate detection methods to improve patient outcomes and prevent complications. However, existing diagnostic approaches often lack sensitivity, specificity, or rapid response times, highlighting the need for innovative biosensing solutions. In response to this challenge, we developed a peptide-based electrochemical biosensor for the specific detection of Gardnerella vaginalis. The sensor was designed to achieve high sensitivity, selectivity, and stability, with detection performed through electrochemical techniques. Cyclic voltammetry (CV) was employed to monitor electron transfer kinetics at the electrode surface, while electrochemical impedance spectroscopy (EIS) provided insights into changes in resistance and capacitance during peptide binding. The sensor fabrication involved covalently bonding anti-Gardnerella vaginalis peptides to a gold nanoparticle (AuNP)-modified graphene electrode, significantly enhancing bioreceptor immobilization stability and increasing the surface area for target binding interactions. The incorporation of AuNPs improved signal amplification due to their high surface-to-volume ratio and excellent conductivity, leading to enhanced sensor performance. The biosensor demonstrated a low detection limit (LOD) of 0.02305 μg/mL, with a rapid response time of 5 min across various concentrations of the target Gardnerella vaginalis antigen. The results confirmed specific and selective binding to the pathogen marker, with minimal interference from non-target species, ensuring high accuracy. The combination of graphene, AuNPs, and peptide bioreceptors resulted in robust signal enhancement, making this biosensor a promising tool for fast and reliable point-of-care diagnostics in clinical settings.

Authors

Publication Details

Journal
Chemosensors
Published
2025-03-19
DOI
https://doi.org/10.3390/chemosensors13030111
Citations
1
Primary Topic
Reproductive tract infections research
Type
article
Field-Weighted Citation Impact
1.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gold Nanoparticle-Enhanced Graphene Immunosensor for Rapid Detection of Gardnerella vaginalis in Clinical Diagnostics

Tomasz Łęga, Beata Gromadzka, Kasjan Szemiako, Sabina Żołędowska et al.
1 citations
Chemosensors
Reproductive tract infections research
1.18
article

Gold Nanoparticle-Enhanced Graphene Immunosensor for Rapid Detection of Gardnerella vaginalis in Clinical Diagnostics

Tomasz Łęga, Beata Gromadzka, Kasjan Szemiako, Sabina Żołędowska, Dawid Nidzworski, Marta Sosnowska, Wioleta Lewandowska
article en
1 citations

Abstract

The global market increasingly demands alternative rapid diagnostic tools, such as disposable biosensors, to meet the growing need for point-of-care clinical testing of infectious diseases. Bacterial vaginosis (BV), a common infection caused by Gardnerella vaginalis, requires efficient and accurate detection methods to improve patient outcomes and prevent complications. However, existing diagnostic approaches often lack sensitivity, specificity, or rapid response times, highlighting the need for innovative biosensing solutions. In response to this challenge, we developed a peptide-based electrochemical biosensor for the specific detection of Gardnerella vaginalis. The sensor was designed to achieve high sensitivity, selectivity, and stability, with detection performed through electrochemical techniques. Cyclic voltammetry (CV) was employed to monitor electron transfer kinetics at the electrode surface, while electrochemical impedance spectroscopy (EIS) provided insights into changes in resistance and capacitance during peptide binding. The sensor fabrication involved covalently bonding anti-Gardnerella vaginalis peptides to a gold nanoparticle (AuNP)-modified graphene electrode, significantly enhancing bioreceptor immobilization stability and increasing the surface area for target binding interactions. The incorporation of AuNPs improved signal amplification due to their high surface-to-volume ratio and excellent conductivity, leading to enhanced sensor performance. The biosensor demonstrated a low detection limit (LOD) of 0.02305 μg/mL, with a rapid response time of 5 min across various concentrations of the target Gardnerella vaginalis antigen. The results confirmed specific and selective binding to the pathogen marker, with minimal interference from non-target species, ensuring high accuracy. The combination of graphene, AuNPs, and peptide bioreceptors resulted in robust signal enhancement, making this biosensor a promising tool for fast and reliable point-of-care diagnostics in clinical settings.

ChemosensorsVol. 13(3)
Narodowe Centrum Badań i Rozwoju
Openalex Percentile: Top 23%
Reproductive tract infections research
1.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.