Frequency-swept feedback interferometry ranging method based on resonant-cavity enhancement

Addressing the issue of low measurement accuracy of conventional Frequency Sweep Interferometry (FSI) ranging methods for long-distance non cooperative targets. This work proposed a Frequency-Swept Feedback Interferometry (FSFI) ranging method based on resonant cavity enhancement for long-distance non-cooperative targets measurement and weak signal detection. The FSFI ranging method has simpler and contact system setup, which also has high precision and sensitivity. After experimental verification, it was found that with a target of oxidized black aluminum plate at a distance of 16m, the Standard Deviation (STD) was better than 70μm, the measurement accuracy was better than 27μm, and the system ranging resolution was better than 0.13mm when the target feedback light was very weak.

Authors

Institutions

Publication Details

Published
2025-03-19
DOI
https://doi.org/10.1117/12.3041079
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency-swept feedback interferometry ranging method based on resonant-cavity enhancement

Zhigang Liu, Junkang Guo, Kai Tian, Yuqi Yu et al.
Advanced Fiber Optic Sensors
article

Frequency-swept feedback interferometry ranging method based on resonant-cavity enhancement

Zhigang Liu, Junkang Guo, Kai Tian, Yuqi Yu, Zian Wang, Weijin Meng
article en

Abstract

Addressing the issue of low measurement accuracy of conventional Frequency Sweep Interferometry (FSI) ranging methods for long-distance non cooperative targets. This work proposed a Frequency-Swept Feedback Interferometry (FSFI) ranging method based on resonant cavity enhancement for long-distance non-cooperative targets measurement and weak signal detection. The FSFI ranging method has simpler and contact system setup, which also has high precision and sensitivity. After experimental verification, it was found that with a target of oxidized black aluminum plate at a distance of 16m, the Standard Deviation (STD) was better than 70μm, the measurement accuracy was better than 27μm, and the system ranging resolution was better than 0.13mm when the target feedback light was very weak.

Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 96%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.