A Self Calibration Oxide Film Thickness Measurement Method Based on Stacked Array Coils

Zircaloy fuel cladding is the first pressure boundary of a nuclear power plant, the reliability of which is crucial to maintaining the nuclear safety. Since the oxide film accumulated on the cladding surface decreases the thermal conductivity and accelerates the corrosion rate of the fuel rods, it is essential to accurately assess the oxide film thickness. Eddy current testing (ECT) is the predominant technology for measuring oxide film thickness in pool-side inspections. By far, ECT requires pre-calibration, which requires expensive calibration samples and is time-consuming. This article presents a novel ECT technology with stacked array coils that are separated by the insulation layers with a thickness of tens of microns. These coils are excited successively in chronological order and the induced voltages are recorded each time, resulting in a data matrix. The distances of coils serve as the interior thickness standard. A data processing procedure is developed to calculate the oxide film thickness from the matrix without the necessary of pre-calibration. An adaptive weight algorithm is proposed to reduce errors of the calculated thickness. The maximum absolute measurement error is under <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$4.5~\mu $ </tex-math></inline-formula>m, while the weight correction reduces the maximum error to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3.74~\mu $ </tex-math></inline-formula>m. Compared with existing calibration methods, this method appears to streamline the calibration procedure without significantly compromising measurement accuracy.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3552812
Citations
4
Primary Topic
Anodic Oxide Films and Nanostructures
Type
article
Field-Weighted Citation Impact
2.07

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Self Calibration Oxide Film Thickness Measurement Method Based on Stacked Array Coils

Chaofeng Ye, Lisha Peng, Songling Huang, Qi Xiao et al.
4 citations
IEEE Transactions on Instrumentation and Measurement
Anodic Oxide Films and Nanostructures
2.07
article

A Self Calibration Oxide Film Thickness Measurement Method Based on Stacked Array Coils

Chaofeng Ye, Lisha Peng, Songling Huang, Qi Xiao, Ming Li, X.F. Li
article en
4 citations

Abstract

Zircaloy fuel cladding is the first pressure boundary of a nuclear power plant, the reliability of which is crucial to maintaining the nuclear safety. Since the oxide film accumulated on the cladding surface decreases the thermal conductivity and accelerates the corrosion rate of the fuel rods, it is essential to accurately assess the oxide film thickness. Eddy current testing (ECT) is the predominant technology for measuring oxide film thickness in pool-side inspections. By far, ECT requires pre-calibration, which requires expensive calibration samples and is time-consuming. This article presents a novel ECT technology with stacked array coils that are separated by the insulation layers with a thickness of tens of microns. These coils are excited successively in chronological order and the induced voltages are recorded each time, resulting in a data matrix. The distances of coils serve as the interior thickness standard. A data processing procedure is developed to calculate the oxide film thickness from the matrix without the necessary of pre-calibration. An adaptive weight algorithm is proposed to reduce errors of the calculated thickness. The maximum absolute measurement error is under <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$4.5~\mu $ </tex-math></inline-formula>m, while the weight correction reduces the maximum error to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3.74~\mu $ </tex-math></inline-formula>m. Compared with existing calibration methods, this method appears to streamline the calibration procedure without significantly compromising measurement accuracy.

IEEE Transactions on Instrumentation and MeasurementVol. 74
ShanghaiTech University (CN), China General Nuclear Power Corporation (China) (CN), Tsinghua University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 14%
Anodic Oxide Films and Nanostructures
2.07
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.