An IoT-Enabled Wearable Health Monitor for Synchronized ExG, PPG, and BioZ Measurement

The multimodal wearable health monitor is designed for patients with chronic conditions and leverage edge data preprocessing for efficiency. It supports a variety of use cases: a brain monitoring headband for measuring electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS), a chest health patch for sensing electrocardiogram (ECG), RR intervals (RRIs), bioimpedance (BioZ), and photoplethysmogram (PPG), and a fitness legband for recording electromyography (EMG) and PPG. Similar devices can also be connected to a body sensor network (BSN) for comprehensive health monitoring. The system includes a flexible PPG sensor and a data acquisition (DAQ) board with integrated BioZ and biopotential channels. They feature a low input-referred noise level of 25 pArms (BW =10 Hz), <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$6.06~\Omega _{\text {rms}}$ </tex-math></inline-formula> (BW =0.05–4 Hz), and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.77~\mu $ </tex-math></inline-formula>Vrms (BW =0.05–150 Hz). The multimodal health monitor consumes 30.4 mW of power and can operate continuously for 36 h. The flexible sensor, with a 1-cm diameter and a bending radius of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$66.6~\mu $ </tex-math></inline-formula>m, conforms to the skin for versatile detection. Edge data preprocessing and offloading tasks to the PC help reduce data redundancy and latency. The overall platform enables remote real-time monitoring, historical data queries, and email alerts. The results indicate that the average correlation of EEG signals was 96.21% in the eyes-open and eyes-closed tests, and the alpha rhythm was clear. During the breath-holding test, the SpO2 level changed by 10%. In chest synchronization, the heart rate (HR) increased by 2 bpm every 3 s. The mean absolute error (MAE) of the HR test for five subjects was 1.38%, and the mean absolute percentage error (MAPE) was 1.98%.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3552863
Citations
5
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
3.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An IoT-Enabled Wearable Health Monitor for Synchronized ExG, PPG, and BioZ Measurement

Yuying Li, Tianxiang Qu, Zhiliang Hong, Jiawei Xu et al.
5 citations
IEEE Transactions on Instrumentation and Measurement
Non-Invasive Vital Sign Monitoring
3.37
article

An IoT-Enabled Wearable Health Monitor for Synchronized ExG, PPG, and BioZ Measurement

Yuying Li, Tianxiang Qu, Zhiliang Hong, Jiawei Xu, Liheng Liu, Hao Li
article en
5 citations

Abstract

The multimodal wearable health monitor is designed for patients with chronic conditions and leverage edge data preprocessing for efficiency. It supports a variety of use cases: a brain monitoring headband for measuring electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS), a chest health patch for sensing electrocardiogram (ECG), RR intervals (RRIs), bioimpedance (BioZ), and photoplethysmogram (PPG), and a fitness legband for recording electromyography (EMG) and PPG. Similar devices can also be connected to a body sensor network (BSN) for comprehensive health monitoring. The system includes a flexible PPG sensor and a data acquisition (DAQ) board with integrated BioZ and biopotential channels. They feature a low input-referred noise level of 25 pArms (BW =10 Hz), <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$6.06~\Omega _{\text {rms}}$ </tex-math></inline-formula> (BW =0.05–4 Hz), and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.77~\mu $ </tex-math></inline-formula>Vrms (BW =0.05–150 Hz). The multimodal health monitor consumes 30.4 mW of power and can operate continuously for 36 h. The flexible sensor, with a 1-cm diameter and a bending radius of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$66.6~\mu $ </tex-math></inline-formula>m, conforms to the skin for versatile detection. Edge data preprocessing and offloading tasks to the PC help reduce data redundancy and latency. The overall platform enables remote real-time monitoring, historical data queries, and email alerts. The results indicate that the average correlation of EEG signals was 96.21% in the eyes-open and eyes-closed tests, and the alpha rhythm was clear. During the breath-holding test, the SpO2 level changed by 10%. In chest synchronization, the heart rate (HR) increased by 2 bpm every 3 s. The mean absolute error (MAE) of the HR test for five subjects was 1.38%, and the mean absolute percentage error (MAPE) was 1.98%.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Fudan University (CN)
National Key Research and Development Program of China
Openalex Percentile: Top 8%
Non-Invasive Vital Sign Monitoring
3.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.