Laboratory-scale production of tunable, narrow-bandwidth x-rays in the clinical energy regime

The Munich Compact Light Source (MuCLS) is part of a new class of x-ray sources based on inverse Compton scattering. A compact laboratory-scale electron storage ring stores electrons with energies from 29 MeV up to 45 MeV. These electrons collide with an infrared laser pulse from the enhancement cavity, capable of storing up to 300 kW of optical power, resulting in x-rays ranging from 15 keV to 35 keV. The unique properties of the MuCLS beam enable a wide range of medical and biological applications: its narrow tunable spectrum allows for artifact-free quantitative computed tomography (CT) as well as targeting K-edges for coronary angiography and absorption spectroscopy. Its relatively high flux density supports studies in radiation therapy, high-resolution micro-CT, and dynamic imaging of processes such as phase-contrast imaging of small animals, specifically focusing on respiratory processes. Additionally, the partial coherence of MuCLS is essential for phase-contrast and dark-field imaging applications: it enables grating-based phase-contrast radiography and tomography of larger specimens, as well as directional dark-field imaging. Despite its significant potential, the MuCLS is currently constrained by its x-ray energy, which impedes the observation of high-density or strongly absorbing materials, and limits penetration depth. Enhancing the x-ray energy could considerably benefit various fields, enabling the detailed observation of denser bone structures and advancing research in geology and material science. Consequently, our project aims to upgrade the MuCLS enhancement cavity to operate at half the current wavelength in the green spectral region, potentially doubling the x-ray energy output.

Authors

Publication Details

Published
2025-03-19
DOI
https://doi.org/10.1117/12.3042357
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Laboratory-scale production of tunable, narrow-bandwidth x-rays in the clinical energy regime

Martin Dierolf, Franz Pfeiffer, Markus Wurzer, Reinhard Kienberger et al.
1 links
Advanced Radiotherapy Techniques
article

Laboratory-scale production of tunable, narrow-bandwidth x-rays in the clinical energy regime

Martin Dierolf, Franz Pfeiffer, Markus Wurzer, Reinhard Kienberger, Natālija Rīgere, Benedikt Günther
article en

Abstract

The Munich Compact Light Source (MuCLS) is part of a new class of x-ray sources based on inverse Compton scattering. A compact laboratory-scale electron storage ring stores electrons with energies from 29 MeV up to 45 MeV. These electrons collide with an infrared laser pulse from the enhancement cavity, capable of storing up to 300 kW of optical power, resulting in x-rays ranging from 15 keV to 35 keV. The unique properties of the MuCLS beam enable a wide range of medical and biological applications: its narrow tunable spectrum allows for artifact-free quantitative computed tomography (CT) as well as targeting K-edges for coronary angiography and absorption spectroscopy. Its relatively high flux density supports studies in radiation therapy, high-resolution micro-CT, and dynamic imaging of processes such as phase-contrast imaging of small animals, specifically focusing on respiratory processes. Additionally, the partial coherence of MuCLS is essential for phase-contrast and dark-field imaging applications: it enables grating-based phase-contrast radiography and tomography of larger specimens, as well as directional dark-field imaging. Despite its significant potential, the MuCLS is currently constrained by its x-ray energy, which impedes the observation of high-density or strongly absorbing materials, and limits penetration depth. Enhancing the x-ray energy could considerably benefit various fields, enabling the detailed observation of denser bone structures and advancing research in geology and material science. Consequently, our project aims to upgrade the MuCLS enhancement cavity to operate at half the current wavelength in the green spectral region, potentially doubling the x-ray energy output.

Affordable and clean energy
Openalex Percentile: Top 93%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.