Reconfigurable integrated photonic device to test Born’s rule

Born’s rule claims that quantum interference occurs only between pairs of paths. Any deviation from this rule can be measured through multi-arm interferometers. For this reason, utilizing the femtosecond laser micromachining technique, we realize a reconfigurable integrated three-path interferometer in which, by means of optical switches, we can close or open the optical path at will, so that all interference contributions can be measured individually. We measured the normalized contribution of the third-order interference term, quantified by the Sorkin’s parameter observing a result of k = −4.677 × 10<sup>−4</sup> with a standard deviation of kstd = 8.394 × 10<sup>−4</sup> . To increase the sensitivity of this measurement, single photons can be used to suppress errors caused by the nonlinearity of the detectors.

Authors

Institutions

Publication Details

Published
2025-03-19
DOI
https://doi.org/10.1117/12.3041781
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reconfigurable integrated photonic device to test Born’s rule

Giacomo Corrielli, Josefine Krause, Roberto Osellame, Tobias Vogl et al.
Photonic and Optical Devices
article

Reconfigurable integrated photonic device to test Born’s rule

Giacomo Corrielli, Josefine Krause, Roberto Osellame, Tobias Vogl, Giulio Gualandi
article en

Abstract

Born’s rule claims that quantum interference occurs only between pairs of paths. Any deviation from this rule can be measured through multi-arm interferometers. For this reason, utilizing the femtosecond laser micromachining technique, we realize a reconfigurable integrated three-path interferometer in which, by means of optical switches, we can close or open the optical path at will, so that all interference contributions can be measured individually. We measured the normalized contribution of the third-order interference term, quantified by the Sorkin’s parameter observing a result of k = −4.677 × 10<sup>−4</sup> with a standard deviation of kstd = 8.394 × 10<sup>−4</sup> . To increase the sensitivity of this measurement, single photons can be used to suppress errors caused by the nonlinearity of the detectors.

Center for Biomolecular Nanotechnologies (IT), Friedrich Schiller University Jena (DE), Politecnico di Milano (IT)
Openalex Percentile: Top 96%
Photonic and Optical Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.