Effect of different airway devices on ventilation during cardiopulmonary resuscitation
In human cadavers undergoing CPR, mechanical ventilation through a face mask or SGA versus an ETT was associated with lower VTe, lower Pmax, and higher leakage values in human cadavers during CPR. Head and thorax elevation reduce face mask and SGA airway leakage during CPR and increase VTe.
Authors
- Julie Fontecave-Jallon (ORCID: https://orcid.org/0000-0001-5764-3144)
- Matthew A. Fischer (ORCID: https://orcid.org/0000-0002-4797-7412)
- Nicolas Segond (ORCID: https://orcid.org/0000-0002-1049-9816)
- Guillaume Debaty
- Keith G. Lurie
- Alexandre Bellier (ORCID: https://orcid.org/0000-0003-0907-0315)
- Paweł Podsiadło (ORCID: https://orcid.org/0000-0002-1069-2659)
Institutions
- Institut polytechnique de Grenoble (FR)
- Centre National de la Recherche Scientifique (FR)
- Jan Kochanowski University (PL)
- Centre Hospitalier Universitaire de Grenoble (FR)
- VetAgro Sup (FR)
- Hennepin Healthcare Research Institute (US)
- Université Grenoble Alpes (FR)
Publication Details
- Journal
- Resuscitation
- Published
- 2025-03-19
- DOI
- https://doi.org/10.1016/j.resuscitation.2025.110584
- Citations
- 5
- Primary Topic
- Cardiac Arrest and Resuscitation
- Type
- article
- Field-Weighted Citation Impact
- 11.27
Funders
- Université Grenoble Alpes