ROI-summed analysis for improved fluorescence lifetime fitting accuracy and precision

Laser-scanning multiphoton microscopy with time-correlated single photon counting (TCSPC) enables fluorescence lifetime imaging microscopy (FLIM) with high spatial and temporal resolution, albeit with limited imaging speed. FLIM images are typically analyzed at the pixel level by fitting pixel decays to multiexponential decay models and assigning lifetimes. Yet, often, only cell-level lifetime parameters are used in statistical analyses. Therefore, pixel-level lifetime parameters are averaged over the cell mask to produce single-cell lifetime parameters. This analysis pipeline is inefficient and introduces variability and bias to the results. We characterize fitting the aggregate decay from all cell pixels as a more accurate and precise method of obtaining cell-level lifetime statistics with shorter integration times.

Authors

Publication Details

Published
2025-03-19
DOI
https://doi.org/10.1117/12.3043430
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ROI-summed analysis for improved fluorescence lifetime fitting accuracy and precision

Danielle E. Desa, Kayvan Samimi, Melissa C. Skala, Dan L. Pham
2 citations
Analytical Chemistry and Sensors
1.47
article

ROI-summed analysis for improved fluorescence lifetime fitting accuracy and precision

Danielle E. Desa, Kayvan Samimi, Melissa C. Skala, Dan L. Pham
article en
2 citations

Abstract

Laser-scanning multiphoton microscopy with time-correlated single photon counting (TCSPC) enables fluorescence lifetime imaging microscopy (FLIM) with high spatial and temporal resolution, albeit with limited imaging speed. FLIM images are typically analyzed at the pixel level by fitting pixel decays to multiexponential decay models and assigning lifetimes. Yet, often, only cell-level lifetime parameters are used in statistical analyses. Therefore, pixel-level lifetime parameters are averaged over the cell mask to produce single-cell lifetime parameters. This analysis pipeline is inefficient and introduces variability and bias to the results. We characterize fitting the aggregate decay from all cell pixels as a more accurate and precise method of obtaining cell-level lifetime statistics with shorter integration times.

Affordable and clean energy
Openalex Percentile: Top 21%
Analytical Chemistry and Sensors
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.