SPAD array detector enables large localization range for simple and robust MINFLUX

The MINFLUX concept significantly enhances the spatial resolution of single-molecule localization microscopy (SMLM) by overcoming the limit imposed by the fluorophore’s photon counts. Typical MINFLUX microscopes localize the target molecule by scanning a zero-intensity focus around the molecule in a circular trajectory, with smaller trajectory diameters yielding lower localization uncertainties for a given number of photons. Since this approach requires the molecule to be within the scanned trajectory, MINFLUX typically relies on a photon-demanding iterative scheme with decreasing trajectory diameters. This approach is prone to misplacements of the trajectory and increases the system’s complexity. In this work, we introduce ISM-FLUX, a novel implementation of MINFLUX using image-scanning microscopy (ISM) with a single-photon avalanche diode (SPAD) array detector. ISM-FLUX provides precise MINFLUX localization within the trajectory while maintaining conventional photon-limited uncertainty outside it. The robustness of ISM-FLUX localization results in a larger localization range and greatly simplifies the architecture, which may facilitate broader adoption of MINFLUX.

Authors

Publication Details

Published
2025-03-19
DOI
https://doi.org/10.1117/12.3042266
Primary Topic
Advanced Optical Sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SPAD array detector enables large localization range for simple and robust MINFLUX

Eli Slenders, Giuseppe Vicidomini, Alessandro Zunino, Sanket Patil et al.
Advanced Optical Sensing Technologies
article

SPAD array detector enables large localization range for simple and robust MINFLUX

Eli Slenders, Giuseppe Vicidomini, Alessandro Zunino, Sanket Patil, M. Held
article en

Abstract

The MINFLUX concept significantly enhances the spatial resolution of single-molecule localization microscopy (SMLM) by overcoming the limit imposed by the fluorophore’s photon counts. Typical MINFLUX microscopes localize the target molecule by scanning a zero-intensity focus around the molecule in a circular trajectory, with smaller trajectory diameters yielding lower localization uncertainties for a given number of photons. Since this approach requires the molecule to be within the scanned trajectory, MINFLUX typically relies on a photon-demanding iterative scheme with decreasing trajectory diameters. This approach is prone to misplacements of the trajectory and increases the system’s complexity. In this work, we introduce ISM-FLUX, a novel implementation of MINFLUX using image-scanning microscopy (ISM) with a single-photon avalanche diode (SPAD) array detector. ISM-FLUX provides precise MINFLUX localization within the trajectory while maintaining conventional photon-limited uncertainty outside it. The robustness of ISM-FLUX localization results in a larger localization range and greatly simplifies the architecture, which may facilitate broader adoption of MINFLUX.

Affordable and clean energy
Openalex Percentile: Top 94%
Advanced Optical Sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.